Beijing Starfire Control Technology Co.,Ltd.
北京斯达峰控制技术有限公司
Model SF-2012AH-QG
Cutting Machine
(
C002
)
23
7.
6
. Control Parameters Setting of Height Controller
In the SETUP submenu, press [F6] key to enter the control parameters setting window of height controller. This control feature is
available only when plasma arc voltage control is used along with the height controller manufactured by Microstep, as shown in Fig. 7.7.
Fig. 7.7 Height control function
Arc voltage/height control option
——
This option is editable only when plasma arc voltage control is used along with
the height controller manufactured by Microstep. Take 1 to enable this option.
Fine tuning of control speed
——
The default value is 100. If the control response is found too slow, reduce the value appropriately;
otherwise, increase this value.
Height controller sensitivity(0-40)
——
This value is used to adjust the sensitivity of height controller in the range of 0 to 40. If
vertical vibration is detected, it implies the sensitivity is too high and reducing this value is recommended; if it is found slow in response,
it implies the sensitivity is too low and increasing this value is recommended.
Arc-voltage height control(30-255V)
——
It is equivalent to the height knob of height controller. Larger value will make the cutting
torchhigher; vice versa.
Speed regulation range D
----
It is often set to 100.
Positioning height B ----
The height to raise the cutting torch when the torch hits steel plate in the process of initial location.
Upper/lowerlimit value ----
To adjust the upper and lower limits of height controller
SETUP main menu
Parameters display zone
ESC key
Parameter
setting range
Remarks zone