Version 3.04
| Beijer BFI-P2 User Guide |
61
www.beijerelectronics.com
8.4.4. Parameter Group 9 – User Inputs and Output Programming
Par.
Function
Setting Range
Default Notes
P9-01
Enable Input Source
These parameters allow the user to directly select the source of the various command points.
Parameters are only adjustable if P1-13 = 0. This allows complete flexibility over the drive control
functions, and interaction with the internal Function Block programming environment.
P9-02
Fast Stop Input Source
P9-03
Run Forward Input Source
P9-04
Run Reverse Input Select
P9-05
Latch Function Enable
0
OFF
0
1
ON
P9-06
Reverse Input Source
See above
P9-07
Reset Input Source
P9-08
External Trip Input Source
P9-09
Terminal Control Select Source
P9-10
Speed Reference Source 1
In combination with P9-18 – P9-20, allow selection of several speed reference sources for common
applications.
P9-11
Speed Reference Source 2
P9-12
Speed Reference Source 3
P9-13
Speed Reference Source 4
P9-14
Speed Reference Source 5
P9-15
Speed Reference Source 6
P9-16
Speed Reference Source 7
P9-17
Speed Reference Source 8
P9-18
Speed Reference Select Input 0
See above
P9-19
Speed Reference Select Input 1
P9-20
Speed Reference Select Input 2
P9-21
Preset Speed Select Input 0
P9-22
Preset Speed Select Input 1
P9-23
Preset Speed Select Input 2
P9-24
Acceleration Ramp Select Bit 0
P9-25
Acceleration Ramp Select Bit 1
P9-26
Deceleration Ramp Bit 0
P9-27
Deceleration Ramp Bit 1
P9-28
Motorised Pot Up Input Source
P9-29
Motorised Pot Down Input Source
P9-30
Speed Limit Switch Forward
P9-31
Speed Limit Switch Reverse
P9-33
Analog Output 1 Source
0
Defined by P2-11
0
These parameters allow the user to override
the normal parameter control source for the
associated function, allowing interaction
with the internal Function Block programming
environment.
1
Function block program - digital
2
Function block program - analog
P9-34
Analog Output 2 Source
0
Defined by P2-13
0
1
Function block program - digital
2
Function block program - analog
P9-35
Relay 1 Control Source
0
Defined by P2-15
0
1
Function block program - digital
P9-36
Relay 2 Control Source
0
Defined by P2-18
0
1
Function block program - digital
P9-37
Display Scaling Source Control
0
Defined by P2-21
0
1
Function block program - digital
P9-38
PID Reference Source
0
Defined by P3-05
0
1
Function block program - digital
P9-39
PID Feedback Source
0
Defined by P3-10
0
1
Function block program - digital
P9-40
Torque Reference Source
0
Defined by P4-06
0
1
Function block program - digital
P9-41
Relay 3,4,5 Function
0
Healthy : Tripped : Running
0
1
Function block program - digital
8
Extended P