© BECOM Systems 2020
14
|
30
Hardware User Manual - Argos3D - P33x
Last change: 29 June 2020/Version 12
Figure 4-1: Argos3D - P33x connector location
a.
Power Connector
b.
Ethernet
c.
General purpose input 1 & 2
d.
General purpose output 1 & 2
e.
Modulation Light Interface (not supported, please do not use)
f.
Trigger
g.
RS232 / RS485 (functionality depends on firmware version)
h.
DIP-Switch
i.
Reset-Button
j.
Debug-UART
k.
Status LED
4.3.1
Power Connector (a)
This 3.5mm terminal connector allows plugging a cable entry plug like
691361100002
from Würth Elektronik.
Compatible connectors from other manufacturers may be found as well.
No.
Signal
Type
Description
1
VIN
P
Positive power supply
2
GND
P
Power ground
Table 4-1: Power connector description
Voltage range: 18V to 30V.
Note
Use inherently limited power sources only!
4.3.2
Ethernet and PoE (b)
This is a standard straight RJ45 10/100/1000 Base-T compatible Ethernet connector.
The Argos3D-P330 and Argos3D-P331 supports PoE++ as alternative power source. Please use a valid PoE++ (90W)
injector or switch only. Using another PoE standard may cause the camera to be not fully operational. Please
check the status of your PoE connection in the StatusRegister. Please refer to the Software User Manual for
additional information and a register description.
4.3.3
General purpose input 1 & 2 (c)
This 4 pole 3.5mm terminal connector allows plugging a cable entry plug like
691361100004
from Würth Elektronik.