© BECOM Systems 2020
16
|
30
Hardware User Manual - Argos3D - P33x
Last change: 29 June 2020/Version 12
No.
Signal
Type
Description
1
TriggerOUT
O (open drain with internal 1k
1)
pull-up to 5V) Trigger Output
2
TriggerIN
I
Max Input Voltage: 20V
Max High Threshold: 3,3V
Min Low Threshold: 0,6V
Trigger Input
3
GND
P
Power ground
Table 4-4: Trigger connector description
Note
The usage of this interface may depend on the firmware version.
1) Depends on camera version. Only valid for version >V1.1.0 (P330, P331) and >V1.0.0 (P332).
Figure 4-2: Example schematic for an external trigger circuit
Figure 4-3: timing diagram of the hardware trigger signal, triggers on rising edge.
4.3.6
RS232/RS485 (g)
This 3 pole 3.5mm terminal connector allows plugging a cable entry plug like
691361100003
from Würth Elektronik.