© BECOM Systems 2020
23
|
30
Hardware User Manual - Argos3D - P33x
Last change: 29 June 2020/Version 12
𝐹𝐼𝑇𝑃 = 𝑡
𝐼𝑁𝑇
[𝑚𝑠] ∙ 𝑓𝑝𝑠 [
1
𝑠
] ∙ 4
TBD
Figure 6-4: Expected cooling plate temperature depending on frame-rate integration time product
6.3.5
Integration Time vs. Frame-rate
The following table shows recommended frame-rate integration time combinations depending on the ambient
temperature.
Caution
Be careful to not stress the device beyond the limits, otherwise you may damage the device.
TBD
Figure 6-5: Integration time vs. frame-rate
The diagram takes
care to limit the FITP in a way that the temperature on the cooling plate doesn’t exceed 70°C.
6.4
Mechanical Outline
All dimensions are given in mm.
Mechanical outline of the ‘Bounding Box’: