Mounting and wiring
EM7004
21
Version: 2.0
• In the case 32 and 64 channel terminal modules (KMxxx4 and KMxxx8 or EMxxx4 and EMxxx8) you
now lever the second unlatching hook on the right-hand side of the terminal module upwards in the
same way.
• Pull (4) the terminal module away from the mounting surface.
3.4
Installation positions
Attention
Constraints regarding installation position and operating temperature range
Please refer to the technical data for a terminal to ascertain whether any restrictions re-
garding the installation position and/or the operating temperature range have been speci-
fied. When installing high power dissipation terminals ensure that an adequate spacing is
maintained between other components above and below the terminal in order to guarantee
adequate ventilation!
Содержание EM7004
Страница 2: ......
Страница 23: ...Mounting and wiring EM7004 23 Version 2 0 Fig 18 Other installation positions...
Страница 59: ...Commissioning EM7004 59 Version 2 0 Fig 68 TCP IP setting for the Ethernet port...
Страница 69: ...Commissioning EM7004 69 Version 2 0 Fig 86 EtherCAT terminal in the TwinCAT tree left TwinCAT 2 right TwinCAT 3...