TwinCAT tabs
CXxxxx-M930/B930
21
Version: 1.1
4.3.3
Device
1
2
3
4
5
No.
Description
1
Information on MAC address, VendorID and DeviceID of the device.
2
This option can be used to extend the name via a PLC program. The
extension consists of a three-digit numerical value.
The value must be entered in the PLC program as a constant value and
must be available at the start of the PLC program. Then link the value to the
variable PnIoBoxCtrl.
3
With this option, the name is taken from the tree view.
4
This option only applies to Windows CE. In delivery state the PROFINET IP
address for the CCAT interfaces is registered with the operating system.
This enables you to access the device via TCP/IP mechanisms when
TwinCAT is in RUN mode.
Enable this option if you do
not
want the PROFINET IP address to be
registered with the operating system.
5
These fields can be used to change the InstanceID and FrameID. However,
the default settings are adequate for most applications.
The Instance ID is incorporated into the formation of the UUID object. The
settings should therefore only be changed in exceptional cases.