Appendix
BC3150
98
Version: 2.1.0
Fig. 89: Status messages relating to the firmware update
8.4
General operating conditions
The following conditions must be met in order to ensure flawless operation of the fieldbus components.
Environmental conditions
Operation
The components may not be used without additional protection in the following locations:
• in difficult environments, such as where there are corrosive vapors or gases, or high dust levels
• in the presence of high levels of ionizing radiation
Condition
Permissible range
Permissible ambient temperature during operation
see technical data
Installation position
variable
Vibration resistance
conforms to EN 60068-2-6
Shock resistance
conforms to EN 60068-2-27
EMC immunity
conforms to EN 61000-6-2
Emission
conforms to EN 61000-6-4
Transport and storage
Condition
Permissible range
Permissible ambient temperature during storage
-25°C... +85°C
Relative humidity
95 %, no condensation
Free fall
up to 1 m in the original packaging
Protection classes and types
Condition
Permissible range
Protection class in accordance with IEC 536 (VDE
0106, Part 1)
A protective conductor connection to the profile rail is
necessary!
Protection class conforms to IEC 529
IP20 (protection against contact with a standard test
finger)
Protection against foreign objects
Less than 12 mm in diameter
Protection against water
no protection
Содержание BC3150
Страница 1: ...Documentation BC3150 Bus Terminal Controller for PROFIBUS DP 2 1 0 2017 07 11 Version Date...
Страница 2: ......
Страница 45: ...Parameterization and Commissioning BC3150 45 Version 2 1 0 Fig 41 Sample for entering associated bytes...
Страница 57: ...Programming BC3150 57 Version 2 1 0 Fig 55 Build...
Страница 87: ...PROFIBUS BC3150 87 Version 2 1 0 Fig 78 RS485 topology with 3 segments and 2 repeaters...