Mechanical installation
68
───
Version: 1.0
eXtended Transport System
7.6
Mover
Better running characteristics
Beckhoff recommends greasing the running surfaces on the curved
rails with Vaseline before mounting the movers and commissioning
the XTS Hygienic.
1
2
► Grease the running surfaces on both sides of the curved rails 1
and 2 with Vaseline
2
1
► Loosen and remove screws 1
► Remove lock 2
1
► Screw set screw 1 into the module
1
► Push guard plate 1 over the set screw onto the module
Содержание ATH2000-0250
Страница 1: ...eXtended Transport System XTS Hygienic Operating Instructions EN 5 7 2020 Version 1 0...
Страница 2: ......