Operating Instructions SWA 200II
19
E
N
G
L
I
S
H
Please note that a function switch can only have one setting. Therefore, only either awning or rain awning or blind or
conservatory blind or conservatory awning or skylight mode can be set.
The function switches are located within the keyboard. Grey DIP switches do not have any meaning for the relevant
function!
Installation mode
1
2
3
4
5
6
7
8
ON
OFF
The installation mode serves for functional control during installation. All times are shortened,
except for the running time.
Selecting the type of awning
Awning
1
2
3
4
5
6
7
8
ON
OFF
In automatic mode, a light intensity controlled retraction or extension of the awning occurs.
The wind alarm overrides all functions.
Blind
The functions are identical to awning mode. In addition, after expiry of the descent running time, the slats are
reversed in accordance with the set reversal time.
1
2
3
4
5
6
7
8
ON
OFF
Reversal time 0.4 sec.
1
2
3
4
5
6
7
8
ON
OFF
Reversal time 0.5 sec.
1
2
3
4
5
6
7
8
ON
OFF
Reversal time 0.7 sec.
1
2
3
4
5
6
7
8
ON
OFF
Reversal time 1.0 sec.
Rain awning
1
2
3
4
5
6
7
8
ON
OFF
The functions are identical to awning mode, but the rain sensor makes the system extend in
the event of rain.
Conservatory awning
1
2
3
4
5
6
7
8
ON
OFF
If a room thermostat is connected, the awning is not extended as soon as the set light thresh-
old is exceeded. First of all only the sun indicator flashes. The awning is only released when the set interior tempera-
ture is reached. The described function is only active in automatic mode.
Conservatory blind
1
2
3
4
5
6
7
8
ON
OFF
The function is identical to the conservatory awning setting. In addition, after expiry of the
descent running time, the slats are reversed. To establish the reversal time, transfer the setting of function keys 5
and 6 from blind mode.
Skylight
If the set conservatory temperature is exceeded, the skylight is brought into ventilating position by a control impulse
(3 or 6 seconds). If the set room temperature is exceeded for the duration of the temperature delay time (1-40 min.),
the window is opened fully.
1
2
3
4
5
6
7
8
ON
OFF
1
2
3
4
5
6
7
8
ON
OFF
Control impulse for open 6 sec.
1
2
3
4
5
6
7
8
ON
OFF
Control impulse for open 3 sec.
Function Switches