Operating Instructions SWA 200II
21
E
N
G
L
I
S
H
Technical Data
SWA 200 II
Wind response delay
3 seconds
(awning retracts)
Wind release delay
1-40 minutes (adjustable)
(awning control released again)
Rain response delay
3 seconds
(awning retracts)
Rain release delay
1-40 minutes (adjustable)
(awning control released again)
Sun response delay
90 seconds
(awning extends)
Sun retraction delay
1-40 minutes (adjustable)
(awning retracts)
Running time monitoring
adjustable between 7 sec. - 5 minutes
Additional connections:
power supply 230 V
pot. free outputs (motor)
max. 2 LS10 light sensors
AN1 or AN2 wind sensor
power supply for AN1 heating
RS 200 rain sensor
RTR 200 room thermostat (closing contact)
external key inputs, centr./individual
control output for external fan
individual key
Plastic housing dimensions:
115 x 190 x 62 mm (LxWxD)
Power supply:
230V, 50 Hz
Max. contact load:
8A/230V, cos
ϕ
= 1; 5A/230V, cos
ϕ
> 0.5
Unit protection:
4 amp slow-blow fuse
Wind setting range:
from 0-30m/s
Sun setting range:
from 0-60kLux
Push-button switches:
Up/down
Selector switches:
Manual/automatic
LS10 light sensor
Weatherproof material
Temperature range - 25(C to + 75(C
Output current 20 mA at 60 kLux
AN2
Manufactured in weatherproof material
Located in two rust-free and sealed ball bearings -
measuring range from 1-30m/sec.
Ambient temperature from -25°C to +75°C
Length of connection cable 1m (2x0, 75mm
2
)
Wind sensors
AN1
Manufactured in weatherproof material
Located in two rust-free and sealed ball bearings - measu-
ring range from 1-30m/sec.
Ambient temperature from -25°C to +75°C
Connection via 5 pin diode plug
The AN1 also has a built-in heating unit, in order to guaran-
tee perfect functioning even in the event of frost.