If the drive is used for shading solutions in a specially marked area (e.g., escape routes, hazard zones,
safety areas), compliance with all applicable regulations and standards must be ensured.
•
Once the drive has been installed, the fitter must mark the used tubular drive in the “Technical data”
chapter and make a note of the installation position.
Caution
Safety instructions for avoiding serious injuries.
•
When electrical or electronic equipment and units are operated, certain components,
e.g., the power supply unit, are live. Physical injuries or damage to property can result in
the event of unauthorised interventions or failure to heed warnings.
•
Be careful when touching the tubular drive, as it heats up during operation for technical
reasons.
•
Before installation, shut down all lines and control devices that are not essential for op-
eration.
•
Crushing or shearing points must be avoided or protected.
•
When installing the drive, all-pole disconnection from the mains with a contact gap of at
least 3 mm per pole must be provided (EN 60335).
•
If the mains connecting cable is damaged, it may only be replaced by the manufacturer.
If the drive has a plug-in connecting cable, it must be replaced with the same type of
mains connecting cable, which is available from the drive manufacturer.
Attention
Safety instructions for avoiding property damage.
•
Ensure that there is adequate clearance between moving parts and adjacent objects.
•
The drive must not be carried by the mains connecting cable.
•
All latching connections and fastening screws on the brackets must be checked to en-
sure that they are secure.
•
Ensure that nothing rubs against the tubular drive, such as shading solution attach-
ments, screws, etc.
•
The drive must be fitted horizontally.
Intended use
The type of tubular drive described in these instructions is intended solely for the operation of awnings, cassette awnings, screens,
drop-arm awnings and conservatory shades.
It may only be used in networked systems if all the individual drives are exactly synchronised and reach the limit positions at the
same time.
When mounting connection parts on the drive dia. 35 mm PXX/XX, only use screws EJOT Delta PT 40x12 WN 5454 Torx (9900 000
545 4).
For roller shutter applications, please use only the types of tubular drive designed for this purpose.
This type of tubular drive is designed for use in single systems (one drive per barrel).
The tubular drive must not be used in potentially explosive areas.
The connecting cable is not suitable for transporting the drive. Always carry the drive by the housing tube.
Other applications, uses and modifications are not permitted in order to protect the safety of the users and others, since these ac-
tions can impair the system’s safety and carry the risk of personal injury and property damage. The drive manufacturer does not
accept liability for damages or injury arising from such actions.
Always observe the information in these instructions when operating or repairing the system. The drive manufacturer does not ac-
cept liability for damage or injury resulting from improper usage.
5 - en
Содержание E12
Страница 25: ...Declaration of conformity 25 en ...
Страница 26: ...26 ...
Страница 27: ...27 ...
Страница 28: ......