background image

Attention

Safety instructions for avoiding property damage.

Ensure that there is adequate clearance between moving parts and adjacent objects.

The drive must not be carried by the mains connecting cable.

All latching connections and fastening screws on the brackets must be checked to en-

sure that they are secure.

Ensure that nothing rubs against the tubular drive, such as shading solution attach-

ments, screws, etc.

Intended use

PR+SMI

PS(+)SMI

The PR+SMI type of tubular drive described in these instruc-
tions is intended solely for the operation of roller shutters.

This type of tubular drive supports not only curtain attachment
by means of springs but also mechanical anti-lifting devices
(e.g., Zurfluh-Feller, Simu, GAH Alberts and Deprat). These are
detected automatically.

For sun protection applications, please use only the types of tu-
bular drive designed for this purpose.

The PS(+)SMI type of tubular drive described in these instruc-
tions is intended solely for the operation of awnings, screens
and conservatory shades.

It may only be used in networked systems if all the individual
drives are exactly synchronised and reach their limit positions
at the same time.

The "+" type of tubular drive has been designed particularly for
the operation of cassette awnings with a higher requirement for
closing torque (clean closure of the cassette).

For roller shutter applications, please use only the types of tu-
bular drive designed for this purpose.

This type of tubular drive is designed for use in single systems (one drive per barrel).
The tubular drive must not be used in potentially explosive areas.
The connecting cable is not suitable for transporting the drive. Always carry the drive by the housing tube.
Other applications, uses and modifications are not permitted in order to protect the safety of the users and others, since these ac-
tions can impair the system’s safety and carry the risk of personal injury and property damage. The drive manufacturer does not
accept liability for damages or injury arising from such actions.
Always observe the information in these instructions when operating or repairing the system. The drive manufacturer does not ac-
cept liability for damage or injury resulting from improper usage.

Attention

Only use anti-lifting devices if the roller shutter laths are sufficiently strong. The closed

curtain must not project beyond the guide tracks or else there is a risk of the joint between

the top two laths being subjected to excessive strain and getting damaged.

6

Содержание L120/11C PS(+)SMI

Страница 1: ...structions SMI Rohrantriebe Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebe...

Страница 2: ...ing the drive adapter with drive adapter safety catch 9 Assembling the drive adapter with screw connection 9 Securing the drive against axial displacement 9 Fixing the drive adapter to the barrel dia...

Страница 3: ...SMI actuators made by the drive manufacturer For plug in connecting cable PS SMI Optimised for sun protection applications Installation without stops is possible from extended point to retracted point...

Страница 4: ...cialists in particular qualified electricians Children from the age of 8 years and persons with reduced physical sensory or mental capabilities or lack of experience and or knowledge may use these dev...

Страница 5: ...er surface from which access to the drive is gained To ensure safe operation of the system after commissioning the limit positions must be correctly set programmed in Drives with a H05VV F connecting...

Страница 6: ...s at the same time The type of tubular drive has been designed particularly for the operation of cassette awnings with a higher requirement for closing torque clean closure of the cassette For roller...

Страница 7: ...he two plug grooves provided for this purpose Check that the cable is properly engaged 1 locating lug Disassembling the plug in connecting cable for tubular drives dia 35 Caution Prior to disassembly...

Страница 8: ...fitter must ensure that the masonry and the system being motorised are sufficiently robust drive torque plus weight of the shading solution Caution Electrical connections may only be carried out by a...

Страница 9: ...drive adapter 1 onto the drive shaft of the tubular drive You can see which way to insert the safety catch 2 from its shape When inserting the drive adapter safety catch 2 into the hole 4 make sure th...

Страница 10: ...n the tube For profile tubes In the case of some drive adapters tolerances of the groove widths in different bar rels can be offset by rotating the drive adapter into a different groove recess These g...

Страница 11: ...s Attention If the allocation table for the SMI tubular drives is incorrect or not available commission ing of the KNX SMI actuator is not possible Connection to the programming unit green yellow blue...

Страница 12: ...been set It may be necessary to delete both limit positions in order to change the direction of rotation There are 4 ways to set the limit positions Lower point to upper point not the stops Lower poin...

Страница 13: ...sound to confirm The limit positions are now set Lower point to upper stop Close to the desired lower limit position Press the programming button of the programming unit for 3 seconds The tubular driv...

Страница 14: ...t be switched Proceed as follows Switch the direction switch 1 to the opposite position The running direction will now have changed Check the running direction again It is only possible to change the...

Страница 15: ...to the desired retracted limit position Press the programming button of the programming unit for 3 seconds The tubular drive makes a click sound to confirm The limit positions are now set Extended pos...

Страница 16: ...n sequence Deleting a limit position when 2 limit positions are programmed green yellow blue brown black grey green yellow blue brown black grey Programming button Travel button Open close to the limi...

Страница 17: ...he programming button and keep it pressed Then press down the travel button and keep it pressed Now release the programming button but continue to keep the travel button pressed Next press the program...

Страница 18: ...imit position and retract immedi ately Tubular drive stops arbitrarily cannot be restarted in the same direction Tubular drive is overloaded Use a more powerful tubular drive Sun protection system kee...

Страница 19: ...system The changeover time for switching the running direction must be at least 0 5 s The switch and control must not execute simultaneous UP and DOWN com mands Protect the electrical connections from...

Страница 20: ...current con sumption A 0 45 0 50 0 75 0 90 1 18 1 10 Mode S2 4 min Degree of protection IP 44 Min tube inside dia meter mm 47 Emission sound pres sure level dB A 70 Technical data dia 58 Type L50 17C...

Страница 21: ...eter mm 60 Emission sound pres sure level dB A 70 This tubular drive is not yet available Sample wiring diagram Controlling one several drive s via a single KNX SMI actuator Central control of up to 8...

Страница 22: ...stallation Direction of rotation as signed limit positions pro grammed Manufacturer s code 2 Becker Antriebe GmbH Project customer Room Signature Project manager building contractor Signature Installi...

Страница 23: ...Declaration of conformity 23...