Lower point to upper point (not the stops)
There is no shading solution length adjustment with this limit position setting.
Close to the desired lower limit position.
Press the programming button of the programming unit for 3 seconds.
▻
The tubular drive makes a “click” sound to confirm.
Then move to the desired upper limit position.
Press the programming button of the programming unit for 3 seconds.
▻
The tubular drive makes a “click” sound to confirm.
►
The limit positions are now set.
Lower point to upper stop
Close to the desired lower limit position.
Press the programming button of the programming unit for 3 seconds.
▻
The tubular drive makes a “click” sound to confirm.
Then open as far as the permanent upper stop.
▻
The tubular drive switches off automatically.
►
The limit positions are now set.
Anti-lifting device in the lower limit position to upper stop
Move down to the lower limit position.
▻
The tubular drive switches off automatically.
Then open as far as the permanent upper stop.
▻
The tubular drive switches off automatically.
►
The limit positions are now set.