Extended position to retracted position without stop
There is no shading solution length adjustment with this limit position setting.
Open to the desired extended limit position.
Press the programming button of the programming unit for 3 seconds.
▻
The tubular drive makes a “click” sound to confirm.
Then open to the desired retracted limit position.
Press the programming button of the programming unit for 3 seconds.
▻
The tubular drive makes a “click” sound to confirm.
►
The limit positions are now set.
Extended position to retracted stop
Open to the desired extended limit position.
Press the programming button of the programming unit for 3 seconds.
▻
The tubular drive makes a “click” sound to confirm.
Then close to the permanent upper stop.
▻
The tubular drive switches off automatically.
►
The limit positions are now set.