BEA 10WIZARDC Скачать руководство пользователя страница 2

75.5101 V1 Sep. 2003 [Rev. 9/22/2003]

 

 

                

 

Page 2 of 16 

SAFETY 
PRECAUTIONS

 

MECHANICAL 
INSTALLATION

 

COMPONENT ID

 

 

 

ESD PRECAUTION 
(ELECTRO-STATIC 
DISCHARGE)

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

• 

Shut off all power going to the header before attempting any wiring procedures. 

• 

Maintain a clean & safe environment when working in public areas. 

• 

Constantly be aware of pedestrian traffic around the door area. 

• 

Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected 
reactions by the door. 

• 

Always check placement of all wiring before powering up to insure that moving door parts will not catch any 
wires and cause damage to equipment. 

• 

Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation. 

 

 

1.  Remove the cover from the unit as shown in picture “A”. After the Wizard is attached to the header, the 

cover may be removed by inserting small screwdriver behind the Wizard and gently prying cover off as 
shown in picture “B”. 

 
 
 
 
 
 
 
 
 

 
2.  Attach mounting template to the center of header as shown (C) – template should be 0”-2” above bottom 

edge of header. Drill the hole marked for wire passage and drill pilot holes for screw mounting (D). 

 

NOTE: Flush mount with bottom of header is necessary for for all neagtive IR angles. 

 
 
 
 
 
 
 
 
 
 
 
 
3.  Insert mounting screws about halfway in (F shown on next page), and install the Wizard onto the 

screws. When in place, tighten screws to secure to header. Leave cover off until mechanical 
adjustments are complete. 

 

 

CABLE 

COVER 

MOUNTING SCREWS 

MOTION SENSOR 

FRONT LENSES 

I.R. REMOTE RECEIVER

PRESENCE SENSOR 

LED INDICATOR 

MANUAL SET-UP 
BUTTONS 

2

nd

 ANTENNA STORAGE 

0-2” 

BOTTOM OF DOOR HEADER 

WIZARD MOUNTING 

TEMPLATE

 

 
Circuit board components are vulnerable to damage by electrostatic discharge (ESD). ESD can cause 
immediate or subtle damage to sensitive electronic parts. An electrostatic charge can build up on the 
human body and then discharge when you touch a board. A discharge can be produced when walking 
across a carpet and touching a board, for example. Before handling any board, make sure you 
dissipate your body’s charge.  

 
CAUTION:  In the event a unit needs to be opened, observe the following precautions.

 

 

• 

Ground yourself by touching a conductive surface of the door or other element connected to common earth ground to discharge 

the static electricity present in your body. 

• 

Avoid walking around while replacing items inside the case, especially if you are on carpet or during conditions of low 

temperature and low humidity. 

• 

Handle the board by the edges only to avoid touching electronic components. 

• 

Store a loose board in an anti-static bag.

OBSOLETE

Содержание 10WIZARDC

Страница 1: ...250 g Housing material ABS LURAN S Color of Housing Anthracite gray standard aluminum or white finish Cable length 8 of six conductor cable MOTION SENSOR PRESENCE SENSOR Technology Microwave and micro...

Страница 2: ...ry for for all neagtive IR angles 3 Insert mounting screws about halfway in F shown on next page and install the Wizard onto the screws When in place tighten screws to secure to header Leave cover off...

Страница 3: ...Page 8 Wizards below SN 52000 will still require a 10IFBWIZARD Other Wiring Notes 1 When connecting to a microprocessed control box the Motion output and presence output wires may be connected to sepa...

Страница 4: ...tern being drawn back towards the door where as the 45 will place the pattern farther away Be certain to walk test detection field and insure compliance with current applicable ANSI standards 1 Insert...

Страница 5: ...bring the pattern nearer or farther from the face of the door by adjusting the tilt angle from 4 to 4 At the standard mounting height one complete clockwise turn of the adjustment screw will move the...

Страница 6: ...ng of 0 7 Default sensitivity value When all parameters have been set press the LOCK key once If you wish to enter a new access code use the 0 9 number keys and enter the new 4 digit code within 20 se...

Страница 7: ...y the red LED flashes quickly After pressing a number button the red LED flashes slowly IMMUNITY motion Immunity reduces the influence of unwanted disturbances within the field of motion detection wit...

Страница 8: ...conds 0 0 30 second learn time 4 Lock The Sensor when complete 5 After the above changes have been made the Wizard will go into the Standard Snow Mode after it goes through 2 auto learn cycles within...

Страница 9: ...ay be accomplished by the use of two Wizard mounted programming buttons The procedures below indicate how to program using these buttons The two set buttons are located at the right side of the Wizard...

Страница 10: ...y returns to standard mode if neither button has been pressed for one minute STEP 2 With all wiring in place apply power to door control and 12 to 24 VAC VDC 5 to 10 to Wizard Once powered observe LED...

Страница 11: ...ontrol or motor Refer to manufacturer s manual for further troubleshooting If door closes with sensor inputs removed fault exists with sensors or related wiring 1 On Off switch at door control in wron...

Страница 12: ...will not unlock when access code is entered 1 Improper code being entered 1 Reset code to the default value of 0000 by performing one of the following a Press the 2 buttons on the Wizard simultaneousl...

Страница 13: ...B 3 of the interface PH 412 249 4100 FAX 412 249 4101 B E A Inc 100 Enterprise Drive Pittsburgh PA 15275 REV 1 OF 1 NONE SIZE CAGE CODE DWG NO FILE OF GDM 20 MAR 2002 GDM A STANLEY DURAGLIDE WITH WIZA...

Страница 14: ...ZARD BROWN BLUE BLACK RED WHITE BROWN BLUE BLACK RED GREEN Reset 0 VDC Part open Exit Off 0 VDC Stop Impulse Pres Impulse 1 C Switch 0 v Pres Impulse 2 18 VDC 0 VDC Outer Impulse Inner Impulse 18 VDC...

Страница 15: ...MPULSE 24 VDC MONITORED SAFETY ONLY PHOTOCELL BESAM UNISLIDE SLIDING DOOR WITH WIZARD SYSTEM SIZE SHEET SCALE A PH 412 249 4100 FAX 412 249 4101 B E A Inc 100 Enterprise Drive Pittsburgh PA 15275 DATE...

Страница 16: ...ITCH PINS 5 6 7 LOOK SEE COM LINE PIN 8 LOOK SEE OUTPUT PINS 17 18 96010 900 QUANTUM SLIDE CONTROL BOX ACCESSORIES 24 VDC PIN 1 PIN 2 ACCESSORIES 24 VAC PINS 3 4 4 PIN 5 PIN EARTH GROUND NEUTRAL MAIN...