BEA 10WIZARDC Скачать руководство пользователя страница 15

75.5101 V1 Sep. 2003 [Rev. 9/22/2003]

 

 

                

 

Page 15 of 16 

ADDENDUM 3 – 
 
WIZARD WITH 
BESAM UNI-SLIDE

 

 
 
 
 
 

GREEN

WHITE

BROWN

BLUE

BLACK

RED

GREEN

WHITE

BROWN

BLUE

BLACK

RED

W

IZARD E

X

T

E

R

IOR

W

IZARD INTE

RIOR

24 V 

TRANSFO

RMER

115 VAC

UniSlide Control

16

15

14

13

12

11

10

9 8

7

6 5

4

3 2

1

INNER I

M

PUL

S

E

- 0 VDC

+ 24 V

D

C

- 0 VDC

OU

TER

 IMPU

LSE

KEY IMPUL

SE

SYNCHRO

NI

Z

ING

 I

N

PUT

SYNCHRO

NI

Z

ING

 O

UT

P

UT

+ 24 V

D

C

-  0 VDC

PRESENCE IMPUL

SE 2

PRESENCE IMPUL

SE 1

STOP IMPUL

S

E

C

-SWITC

H

/MON

ITOR

ED

 IN

N

E

R

 IMPU

LSE

+  24 V

D

C

MONITORED SAFETY/ONL

Y

 PHOTOCEL

L

BESAM UNISLIDE SLIDING DOOR WITH WIZARD SYSTEM

SIZE:

SH

EET:

SC

AL

E:

A  

P

H

: (

4

12

2

49

-4

1

00

   

 F

A

X

: (

41

2)

 2

49

-4

1

01

B.E.A., Inc.

1

0

0

 E

n

te

rp

ris

e

 D

riv

e

  

  

P

itt

sb

u

rg

h

P

A

  

1

5

2

7

5

DATE:

w

w

w

.b

e

a

se

n

so

rs

.c

o

m

CA

GE

 CODE

:

D

WG NO:

F

ILE

 OF:

DRA

WN B

Y

:

RE

V

:

1

 O

F

 1

NTS

Tec

h

 S

upport

8

0

.0

1

6

3

G

D

M

B

1

1

 M

a

2

0

0

3

T

IT

L

E

:  BESAM UNISL

IDE SL

IDING DOOR

             WITH WIZARD SYSTEM

NOTE: 1) DO NOT CONNECT BR

OWN WIRES TO C-SWITCH COMMON. 

            2) OBSERVE POLA

RITY WITH THE BROWN WIRE CONNECTED

                TO GROUND (0 VDC).             3) A JUMPER MUST

 BE 

INSTALLED BETWEEN PINS 

5, 12 ON THE CONTROL

                BO

X T

O

 ALLO

W

 F

O

R

 RE-ENT

RY SENSO

R IN O

N

E-W

AY T

R

AF

F

IC MO

DE T

O

                COMPLY WITH ANSI A156.10  SECTION 8.2.3.

 
 
 
 
 
 
 
 

OBSOLETE

Содержание 10WIZARDC

Страница 1: ...250 g Housing material ABS LURAN S Color of Housing Anthracite gray standard aluminum or white finish Cable length 8 of six conductor cable MOTION SENSOR PRESENCE SENSOR Technology Microwave and micro...

Страница 2: ...ry for for all neagtive IR angles 3 Insert mounting screws about halfway in F shown on next page and install the Wizard onto the screws When in place tighten screws to secure to header Leave cover off...

Страница 3: ...Page 8 Wizards below SN 52000 will still require a 10IFBWIZARD Other Wiring Notes 1 When connecting to a microprocessed control box the Motion output and presence output wires may be connected to sepa...

Страница 4: ...tern being drawn back towards the door where as the 45 will place the pattern farther away Be certain to walk test detection field and insure compliance with current applicable ANSI standards 1 Insert...

Страница 5: ...bring the pattern nearer or farther from the face of the door by adjusting the tilt angle from 4 to 4 At the standard mounting height one complete clockwise turn of the adjustment screw will move the...

Страница 6: ...ng of 0 7 Default sensitivity value When all parameters have been set press the LOCK key once If you wish to enter a new access code use the 0 9 number keys and enter the new 4 digit code within 20 se...

Страница 7: ...y the red LED flashes quickly After pressing a number button the red LED flashes slowly IMMUNITY motion Immunity reduces the influence of unwanted disturbances within the field of motion detection wit...

Страница 8: ...conds 0 0 30 second learn time 4 Lock The Sensor when complete 5 After the above changes have been made the Wizard will go into the Standard Snow Mode after it goes through 2 auto learn cycles within...

Страница 9: ...ay be accomplished by the use of two Wizard mounted programming buttons The procedures below indicate how to program using these buttons The two set buttons are located at the right side of the Wizard...

Страница 10: ...y returns to standard mode if neither button has been pressed for one minute STEP 2 With all wiring in place apply power to door control and 12 to 24 VAC VDC 5 to 10 to Wizard Once powered observe LED...

Страница 11: ...ontrol or motor Refer to manufacturer s manual for further troubleshooting If door closes with sensor inputs removed fault exists with sensors or related wiring 1 On Off switch at door control in wron...

Страница 12: ...will not unlock when access code is entered 1 Improper code being entered 1 Reset code to the default value of 0000 by performing one of the following a Press the 2 buttons on the Wizard simultaneousl...

Страница 13: ...B 3 of the interface PH 412 249 4100 FAX 412 249 4101 B E A Inc 100 Enterprise Drive Pittsburgh PA 15275 REV 1 OF 1 NONE SIZE CAGE CODE DWG NO FILE OF GDM 20 MAR 2002 GDM A STANLEY DURAGLIDE WITH WIZA...

Страница 14: ...ZARD BROWN BLUE BLACK RED WHITE BROWN BLUE BLACK RED GREEN Reset 0 VDC Part open Exit Off 0 VDC Stop Impulse Pres Impulse 1 C Switch 0 v Pres Impulse 2 18 VDC 0 VDC Outer Impulse Inner Impulse 18 VDC...

Страница 15: ...MPULSE 24 VDC MONITORED SAFETY ONLY PHOTOCELL BESAM UNISLIDE SLIDING DOOR WITH WIZARD SYSTEM SIZE SHEET SCALE A PH 412 249 4100 FAX 412 249 4101 B E A Inc 100 Enterprise Drive Pittsburgh PA 15275 DATE...

Страница 16: ...ITCH PINS 5 6 7 LOOK SEE COM LINE PIN 8 LOOK SEE OUTPUT PINS 17 18 96010 900 QUANTUM SLIDE CONTROL BOX ACCESSORIES 24 VDC PIN 1 PIN 2 ACCESSORIES 24 VAC PINS 3 4 4 PIN 5 PIN EARTH GROUND NEUTRAL MAIN...

Отзывы: