background image

 

Page

57 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

 

Outlet Thresholds for device 1, MRP-27 
Threshold values listed next to outlet number. 
Enter outlet number to change associated thresholds. 
 
Outlet  PF (%)   Pwr (W) |  Outlet  PF (%)   Pwr(W) 
   1    100        10    |    13    100        10 
   2    100        10    |    14    100        10 
   3    100        10    |    15    100        10 
   4    100        10    |    16    100        10 
   5    100        10    |    17    100        10 
   6    100        10    |    18    100        10 
   7    100        10    |    19    100        10 
   8    100        10    |    20    100        10 
   9    100        10    |    21    100        10 
  10    100        10    |    22    100        10 
  11    100        10    |    23    100        10 
  12    100        10    |    24    100        10 
 
Enter Request :1

 

Select 2),

 displays Outlet Power 

Factor (PF) Threshold. 

Unit displays the Breaker Circuit 
Threshold Menu with current values. 
 

Select 2),

 changes the Minimum 

Power Threshold level. Enter a value. 

Factory Default is (50w).

 

Breaker Circuit Threshold Menu 
Device 1, Breaker Circuit 1 
Efficiency Threshold: 100, Power Threshold: 10 
 
  Power/VA Power Factor Threshold....1 
  Minimum Power Threshold............2 
 
Enter Request :2

 

Minimum power required to generate an SNMP power factor 
trap if power factor is below threshold. 
 
Enter threshold value: 

 Circuit Power Factor Thresholds....1

  Outlet Power Factor Thresholds.....2 
 
Enter Request :1

 

The unit displays the number of 
outlets on the unit. Select an outlet 
number to change the values for 
Power Factor (PF) Threshold and 
Power Threshold. 

Outlet Circuit Threshold Menu 
Device 1, Outlet 1 
Efficiency Threshold: 100, Power Threshold: 10 
 
  Power/VA Power Factor Threshold....1 
  Minimum Power Threshold............2 
 
Enter Request :

 

  Power/VA ratio threshold as a percent, between 0 and 100, inclusive. 
  Power factors below this value will generate an SNMP trap, if 
enabled and power is above minimum power threshold.  A value of 0 
disables threshold. 
 
  Enter threshold value:

NOTE:

 The Power Factor Threshold SNMP alarm is sent only if both respective values drop 

below the Power Factor Threshold and Power Threshold at the same time. 

Unit displays the Outlet Circuit 
Threshold Menu with Device Outlet 
number and current values. 
 

Select 1)

 changes the Power Factor 

Threshold level. Enter a per cent value 
(%). 

Factory Default is (0%).

 

Содержание MRPr

Страница 1: ...2019 Copyright 2019 Bay Technical Associates Inc 1 1 2019 Modular Remote Power Redundant MRPr ...

Страница 2: ...NU 21 OUTLET CONTROLLER STATUS SCREEN 22 OUTLET HELP OPTIONS 23 RECEPTACLE CONTROLS 23 ON OFF REBOOT LOCK AND UNLOCK 23 STATUS 24 OSTATUS 24 OUTLET CONTROL CONFIGURATION MENU 25 Manage Users 25 Change Outlet Name 28 Enable Disable Confirmation 28 Enable Disable Status Menu 29 Change Unit ID 29 Change Alarm Threshold 29 Change Display Orientation 30 DISPLAY CURRENT ELECTRICAL CHARACTERISTICS 30 LOG...

Страница 3: ...isable 46 Telnet Enable Disable 46 SSH Enable Disable 47 SSH Host Key Generation 47 IP Filter Configuration 47 SNMP Configuration 48 Web Server Configuration 49 MODULE NAME 50 RPC MANAGEMENT 50 Temperature Alarm Threshold 50 Under Voltage Alarm Threshold 51 Over Voltage Alarm Threshold 51 Low Current Alarm Threshold 51 Environmental Sensors 51 Outlet Groups 52 Temperature Units degrees C F 54 RPC ...

Страница 4: ...ZZER AUDIBLE ALARMS 70 DISPLAY CURRENT ELECTRICAL CHARACTERISTICS 71 LOGGING OUT 71 CURRENT USER PASSWORD 71 IDENTIFY CURRENT USER 72 UNIT IDENTIFICATION 72 SETTING SOURCE INPUT PRIMARY 72 SETUP OPTIONS 72 RIPSET 72 BAYTECH PRODUCT WARRANTY 73 EXCEPTIONS 73 BAYTECH EXTENDED WARRANTY 73 TECHNICAL SUPPORT 74 REPAIR POLICY 74 RETURN AUTHORIZATION PROCESS 75 APPENDIX TACACS CONNECTION SCENERIOS 76 HOR...

Страница 5: ...___________________________________________________ 20 Figure 13 Network Port Configuration __________________________________________________________________________ 20 Outlet 1 Outlet Control Help __________________________________________________________________________________ 23 Outlet 2 Outlet Configuration _________________________________________________________________________________ 25 ...

Страница 6: ...r applications of any products specified in this document The information in this document is proprietary to Bay Technical Associates Inc In the interest of improving internal design operational function and or reliability Bay Technical Associates Inc reserves the right to make changes to the products described in this document without notice Bay Technical Associates Inc does not assume any liabil...

Страница 7: ...connect to a local EIA 232 device such as a computer terminal or external modem Most serial computers do not have RJ 45 connections therefore an adapter is provided with this unit to convert from a DE 9 connector to an RJ 45 connector Bay Tech Part No 9FRJ45PC 4 An adapter to convert from a DB 25 connector to an RJ 45 connector is also available from Bay Tech upon request Bay Tech Part No 25FRJ45P...

Страница 8: ...uld be clean and free of extreme temperatures and humidity Allow sufficient space behind the MRP MMP MSP MDP unit for cabling and receptacle connections Access to installation site should be restricted to authorized personnel Installation of these units should be limited to ITE and Telco server environments PRÉPARATION DE L EMPLACEMENT D INSTALLATION Le secteur d installation devrait être propre e...

Страница 9: ...assez pas l estimation courante à C A pour le modèle choisi CAUTION In order to be absolutely removed from the power supply the power cord must be unplugged from the power source ATTENTION Afin d être absolument enlevé de l alimentation d énergie le cordon de secteur doit être débranché de la source d énergie CAUTION For PERMANENTLY CONNECTED EQUIPMENT a readily accessible disconnect device Circui...

Страница 10: ...er status will indicate Off If no power cord is attached to the IN receptacle the circuit breaker status will indicate Off indicating there is no power available to the OUT receptacle 208V 48A Rated Model 60A Maximum Over current protection Device 208V 40A Rated Model 50A Maximum Over current protection Device 208V 24A Rated Model 30A Maximum Over current protection Device 208V 16A Rated Model 20A...

Страница 11: ...mit Data Out 5 RX In Receive Data In 6 N C In No Connection 7 GND Signal Ground 8 DCD In DCD into the MRP Adapter signals Listed are the pin specifications for the BayTech cable and adapters and the terminal COM ports Serial 1 Port Pin out Table Signal RS 232 Port DS RS 232 Port MRP COM Port DE 9 Pin COM Port DB 25 Pin Signal DTR 1 1 4 20 DSR GND 2 2 1 GND RTS 3 3 7 5 CTS TXD 4 4 3 2 RXD RXD 5 5 2...

Страница 12: ... RJ45 to RJ45 Serial 2 RJ08X007 Pin out Serial 3 RJ45 Receptacle Plug Adapters Serial 4 9FRJ45PC Cisco Adapter Pin Out Serial 5 9FRJ45PC 1 Adapter Pin out Use with RJ08X007 Cable And B C switch in C Use with RJ08X007 Cable And B C switch in B ...

Страница 13: ...it s receptacles An illuminated LED signifies the corresponding outlet has power turned on thus the attached equipment has power to it No lit LED signifies no power to the receptacle IMPORTANT If you send the command to reboot a receptacle with a host terminal or modem attached active connection to that terminal or modem is lost and will have to be reestablished IMPORTANT An assigned user is allow...

Страница 14: ...e a menu similar to Figure 4 7 Select number for the Manage Users option You should see a menu similar to Figure 5 8 IMPORTANT NOTE the first user added will be the ADMIN user Type A and press Enter Type the name of the admin user The name is case sensitive 9 Select the user number You should see the user in the menu similar to Figure 6 10 Select Add Outlet s to add a few outlets i e 1 2 4 and pre...

Страница 15: ...Enter until you are asked to Accept Changes Type Y to accept changes or N to decline changes 13 After Accepting or Declining Changes you should get the Network Access Menu Figure 7 14 Select Unit reset to update the external connections Once the reset is completed 1 minute connect the Baytech device to your network using an Ethernet cable 15 If you disabled the DHCP in step 11 you should see a men...

Страница 16: ...t 1 On 18 CKT 5 Outlet 2 On 19 CKT 5 Outlet 3 On 20 CKT 5 Outlet 4 On Type Help for a list of commands MRP 20 MRP 20 help On n cr Turn on an Outlet n 0 1 36 all Off n cr Turn off an Outlet n 0 1 36 all Reboot n cr Reboot an Outlet n 0 1 36 all Status cr MRP 10 Status Config cr Enter configuration mode Lock n cr Locks Outlet s state n 0 1 36 all Unlock n cr Unlock Outlet s state n 0 1 36 all Curren...

Страница 17: ... select the configuration menu type config at the prompt The User Menu allows the admin user to add and delete users change passwords and change the outlet list that displays a user s access to prescribed outlets Select Manage Users from the configuration menu and the following menu appears if the unit has been reset or initial setup User Assigned Outlets C1 1 C1 2 C1 3 C1 4 A Add User D Delete Us...

Страница 18: ...ws the administrator to change the name of the outlets Enable Disable Confirmation Enables Disables the confirmation of choices Example Turn off all outlets Y N Enable Disable Status Menu Enables Disables whether outlet status menu is displayed Change Unit ID Allows the user to change the name of the unit The defaulted is something similar to MRP1 Allows the user to personalize or customize name o...

Страница 19: ...rk Main menu Disconnect Timeguard 5 Data received within the delay period is data not attention character thereby preventing unwanted port disconnection Connect Port ID Echo 6 Echo port name or module port Login Setup 7 Login Menu Serial Telnet Radius TACACS access control manage users Network Port Configuration 8 Network Port IP Address Module Name 9 Change name of module MRP Management 10 Set up...

Страница 20: ...net Mask and Gateway Address or enable the DHCP The Changes must be saved and the module reset for network changes to take effect Network setup Ethernet Address 00 C0 48 00 01 FD IP Address 70 150 140 89 Subnet Mask 255 255 255 224 Default Gateway 70 150 140 65 Connection Inactivity Timeout mins Disabled Carriage Return Translation Enabled Break Length msecs 350 DHCP is Disabled Telnet is Enabled ...

Страница 21: ...dware information Outlet controller firmware F1 11 Options installed Voltage and Current sensors and Internal Temperature Sensor Opening access to internal RPC signifies the processor is checking to see what is installed Enter user name will appear if a user has been assigned to the Outlet Controller Module 1 Attention Character MRP27 2 1 1 MRP27 2 2 2 Outlet Group Control O Status S Configure C U...

Страница 22: ...MOD 6 Outlet 3 On 24 MOD 6 Outlet 4 On Type Help for a list of commands MRP 10 Type Help at the prompt to display a list of commands to change the outlet state outlet configuration and internal sensor measurements NOTE Int Temp unit internal temperature Ext external temperature probe Two environmental ports are available Temperature reads in Fahrenheit or Celsius RH Relative humidity NOTE The user...

Страница 23: ...rom the MRP prompt If the confirmation option is turned on the UNIT will display the following Turn On Outlet 3 Y N Type Y for yes or N for no Likewise typing ON ALL ON 0 or ON at the MRP prompt and responding Y for yes turns On all outlets The OFF n command work similarly as the ON n command The REBOOT n command will reboot or reset equipment attached to corresponding receptacle s When the comman...

Страница 24: ...1 Outlet 2 0 0 A 0 2 A 116 7 V 0 W 4 VA On CKT 1 Outlet 3 0 0 A 0 0 A 116 7 V 0 W 4 VA On CKT 1 Outlet 4 0 0 A 0 1 A 116 7 V 0 W 4 VA On CKT 1 Outlet 5 0 0 A 0 1 A 116 7 V 0 W 4 VA On CKT 2 Outlet 1 0 1 A 0 1 A 117 8 V 0 W 19 VA On CKT 2 Outlet 2 0 0 A 0 1 A 117 8 V 0 W 4 VA On CKT 2 Outlet 3 0 1 A 0 1 A 117 8 V 0 W 19 VA On CKT 2 Outlet 4 0 1 A 0 1 A 117 8 V 0 W 19 VA On CKT 2 Outlet 5 0 0 A 0 1 ...

Страница 25: ...ser number to assign Outlets A D C or R Enter Request NOTE the first assigned user will be the admin user for the outlets Older units will not display the delete option unit a user is added NOTE If the Add user option is NOT present than the maximum number of users have been assigned You will get a message saying No more users can be added User Assigned Outlets C1 1 C1 2 C1 3 C1 4 1 Engineer N Y N...

Страница 26: ... not had a power cycle or unit reset command performed recently before you delete the user in the first position perform a unit reset command from the main menu This action will prevent the unit from having NO Admin user assigned even though the first position user was deleted and there is a second user assigned If the NO Admin condition occurs reset the unit to factory defaults User Assigned Outl...

Страница 27: ...r Enter Outlet number s Type the number of the outlet to be removed from the user s access For example if you want to remove Outlet C1 2 enter the number 2 followed by cr If you want engineer to have access to Outlets C1 2 C1 3 and C1 4 enter the numbers 2 3 and 4 separated by commas followed by cr The unit redisplays the Assigned Outlet Menu of the user with an N for the outlets NOT assigned User...

Страница 28: ...equest 1 Type the number of the outlet to be changed For example to change the name of Outlet 4 type the number 4 at the Enter Request prompt followed by cr The unit will ask if you want to modify the current name Type N to keep the same name or type Y to change the name Y will cause the unit to prompt for a new name Current Outlet Outlet 4 Modify Y N y Enter Type a new receptacle name maximum 16 ...

Страница 29: ... disabled the unit will perform the command and redisplay the previous menu Turn On Outlet 3 Y N Select 4 from the Outlet Control Menu enables the Status menu The unit will display the option to change the current status Default setting is Enabled If this feature is disabled only the prompt appears else the following status menu appears Enable Status Menu Y N y Select 6 from the Outlet Control Men...

Страница 30: ...r Normal Display Y N y Type N to keep the current value or type Y to change the value and enter the new value press Enter and the unit will display next circuit group Circuit breaker 1 buzzer alarm value 12 0 Amps Modify Y N y Enter 15 Circuit breaker 2 buzzer alarm value 12 0 Amps Modify Y N y Default setting is 12 0 Amps Select 1 Circuit Breaker Alarms changes the alarm level per circuit breaker...

Страница 31: ...sword NOTE If you do not have the user s current password delete the user Reinstall user Select option to change password and the unit will respond asking for a new password Type Logout Logoff or Exit at the prompt to logoff from the unit This will close the Outlet Control session Press Enter to open the Outlet Controller session A login prompt may appear if a user has been assign to an outlet New...

Страница 32: ...queuelen 0 Press ENTER to continue Select 2 Network Status contains the MAC address IP address Mask TX RX packets and their status C configuration user current process Active Users USER FROM INTERNAL CONN STATUS PID 1 root localhost Normal 23 C 2 root 70 150 140 69 Normal 490 3 root 70 150 140 66 Normal 492 Strike T CR to terminate a connection process CR to continue Select 3 shows the name of the...

Страница 33: ... Iface interface used to reach the network gateway in this case Baytech network card Kernel IP routing table Destination Gateway Genmask Flags Metric Ref Use Iface 192 168 2 0 255 255 255 0 U 0 0 0 eth0 127 0 0 0 255 0 0 0 U 0 0 0 lo default 192 168 2 1 0 0 0 0 UG 0 0 0 eth0 Press ENTER to continue Select 7 displays a list of Process commands used by the firmware to operate Type T and the unit wil...

Страница 34: ...nt Sensor threshold Firmware Config Download 11 Upload FTP firmware upload and download unit configuration Exit X CR Enter Request NOTE The following message Configuration mode in use signifies a user in the other port is in the Configuration menu Installed Modules 01 Attention Character is Disconnect Time Guard is Disabled Port ID Echo is Disabled Module Name is Universal RPC Network Connectivity...

Страница 35: ...al or Ethernet ports using the menus RTS and DTR Line Drivers can only be configured through the phone line via a modem The default settings are 9600bps 8 data bits no parity one stop bit RTS and DTR High IMPORTANT Communications with the terminal computer connected to the port will be lost until the serial port configuration of the terminal computer matches the unit s serial port Port Device Devi...

Страница 36: ...y it is very likely that these values could be transmitted as data and the transmission would fail Hardware Handshaking This style uses actual hardware lines Like the TX and Rx lines the RTS CTS and DTR DSR lines work together When a receiver is ready for data it will assert the RTS Request to Send line This is then read by the sender at the CTS Clear to Send input indicating it is clear to send t...

Страница 37: ...sed for stop bits the greater the lenience in synchronizing the different clocks but the slower the data transmission rate Parity is a simple form of error checking used in serial communication For even and odd parity the serial port will set the parity bit the last bit after the data bits to a value to ensure that the transmission has an even or odd number of logic high bits For example if the da...

Страница 38: ...ess the network main menu Select 4 from the Network Configuration Menu to change the attention character The unit displays the following The Default is a semi colon Attention Character is Enter Attention Character Select 5 from the Network Configuration Menu ensures reliable binary data transmission by providing a one second Timeguard after the unit receives the attention character If more data is...

Страница 39: ...isable prompt Press Enter to keep same setting Login prompt for serial is Disabled Enable Y N CR for no change If the login has been enabled you will get a prompt similar to the following The default user and password is root and baytech all lower case Universal RPC login root Password Select 2 from the Login setup Menu allows the administrator to add delete users and change their passwords for mu...

Страница 40: ...1 Exit X Enter Request 1 Select 1 to change a user s password The unit displays the following menu User name root Enter old password CR if none If the user does not have a password the RPC will respond for a new password and a confirmation to re enter the new password Enter new password 31 characters Confirm by re entering new password Password change successful Select D Delete user The unit re di...

Страница 41: ...er IP addresses Select 4 Radius Secret sets the shared radius secret A secret can be up to 16 characters and must be exactly the same as the secret stored on the server Select 5 Enable URPC usernames as backup enables URPC usernames as backup login allows an unsecured access until the RADIUS server becomes available Select 6 Radius Login Timeout sets the amount of time the unit will wait for a res...

Страница 42: ... 6 Enable Disable encryption TACACS login Timeout 7 Sets Time units waits for response TACACS Server Port 8 Assign secure TCP port URPC Privilege Level Enable 9 Enable Disable TACACS privilege URPC Privilege Level 10 Set Privilege Level 1 15 Exit X CR Select 4 from the Login Setup Menu displays the TACACS Configuration menu Setting up TACACS To enable TACACS for logins do the following Enable TACA...

Страница 43: ...el Enable enables the unit to send a privilege level to the TACACS server Default is Disabled Select 10 URPC Privilege Level assigns privilege levels 1 is the minimum user privilege and 15 is the root admin privilege level Default is 15 Example of operation Privilege Level enabled set to 10 In tacacs conf file on daemon user1 is configured for exec priv lvl 9 user2 is configured for exec priv lvl ...

Страница 44: ...ecific IP Addresses SNMP provides a message format for communication between a computer and your devices and Web Server Configuration allows web access and sets up options for each Network setup Ethernet Address 00 C0 48 00 01 FD IP Address 70 150 140 89 Subnet Mask 255 255 255 224 Default Gateway 70 150 140 65 Connection Inactivity Timeout mins Disabled Carriage Return Translation Enabled Break L...

Страница 45: ...orm Enter Subnet Mask in dotted decimal form This option is for setting the IP Version 6 The menu options are IPv6 Address Network Prefix Size and Gateway Ethernet Address 00 C0 48 0C A6 C6 IPv6 Address 0 IPv6 Default Gateway IPv6 Address 1 Network Prefix Size 2 Gateway 3 Enter Request The IPv6 address is a 128 bit network address assigned by your network manager for your network The IPv6 Address ...

Страница 46: ...n be from 1 to 120 minutes Default is 0 DISABLED Carriage Return Translation is Enabled Enable Y N CR for no change Break Length is msec 350 Enter break length in milliseconds 10000 0 to disable Select 7 from Network Port Configuration Menu enables or disable the DHCP feature Dynamic Host Configuration Protocol DHCP is a communications protocol that lets network administrators manage centrally and...

Страница 47: ...ion Menu the IP Filter Management Menu allows the admin user to pass or block certain IP Addresses If you have no rules defined the unit may display only options A E C Select 10 from Network Port Configuration Menu allows the user to generate a unique SSH host key for the RPC unit This key is part of the SSH encryption process Each RPC leaving Baytech is shipped with same default SSH host key It i...

Страница 48: ... program Information provided is for the SNMP Agent only Baytech Support will assist with the Agent part only For SNMP Manger assistance refer to the vender manual or contact the vender of the SNMP software you are using NOTE There are a number of shareware MIB Browsers that can be downloaded from the internet to make changes and receive traps for a quick verification test NOTE To use the SNMP fun...

Страница 49: ... 102 Enter new Trap Host IP Address SNMP Trap Host 4 IP Address 192 168 2 136 Enter new Trap Host IP Address Read Gives read access to authorized management stations to all objects in the MIB except the community strings but does not allow write access Write Gives read and write access to authorized management stations to all objects in the MIB but does not allow access to the community strings SN...

Страница 50: ...age have administrator privilege unless a TACACS server and privilege levels are used for authentication IMPORTANCE If a user is still connected to the outlet controller menu or the user does not properly release the controller the Web page will not update Module Name is RPC Enter Module Name 32 chars max Select 9 from the Network Configuration menu changes the unit name Select 1 changes the alarm...

Страница 51: ... Sel M P Identifier Hi V Lvl 1 2 1 MRP10 1300 Select 4 changes the alarm for low current Enter the Selection Sel Number and press Enter Type a value in tenths of a volt i e 100 10 0 amps Sel M P Identifier Low Curr 1 2 1 MRP10 0 Enter voltage threshold value in tenths of a volt Enter low current threshold value in tenths of an amp NOTE M P Module number and Port number Identifier this unit s model...

Страница 52: ...d 4 enable the SNMP traps to be sent if the corresponding threshold had been exceeded NOTE NP No Probe detected NOTE The type Contact signifies the unit does not recognize or detect a probe but still be able to send SNMP Traps Group Name Outlets 1 Router GP A 2 1 1 2 1 2 2 1 3 2 1 4 2 Server Row 2 1 5 2 1 6 2 1 7 2 1 8 3 Radius 2 1 9 2 1 10 2 1 11 2 1 12 4 Server backup 2 1 13 2 1 14 2 1 15 2 1 16...

Страница 53: ...ort outlet Delete ALL outlet groups Y N y The unit displays the following and asks for a name for the new Group Select 3 deletes a specific outlet group select the number of the group to be deleted The unit will display Group Deleted Select 4 renames an outlet group s name select the number of the group to be renamed The unit displays the selected group and prompts for a new name Select 5 modifies...

Страница 54: ...ature NOTE Read the instruction carefully for the feature to operate properly RPC Cascade Mode is Enabled Enabling this feature will allow access and management of a BayTech Remote Power Device through the console EIA 232 port via telnet ssh SNMP http In RPC Cascade Mode normal console port terminal service will operate only when the network cable is disconnected When Cascade Mode is changed URPC ...

Страница 55: ... Outlet 2 15 3 MOD 4 Outlet 3 16 3 MOD 4 Outlet 4 Slave Unit Outlets 17 3 MOD 1 Outlet 1 18 3 MOD 1 Outlet 2 19 3 MOD 1 Outlet 3 20 3 MOD 1 Outlet 4 21 3 MOD 2 Outlet 1 22 3 MOD 2 Outlet 2 23 3 MOD 2 Outlet 3 24 3 MOD 2 Outlet 4 25 3 MOD 3 Outlet 1 26 3 MOD 3 Outlet 2 26 3 MOD 3 Outlet 3 28 3 MOD 3 Outlet 4 29 3 MOD 4 Outlet 1 30 3 MOD 4 Outlet 2 31 3 MOD 4 Outlet 3 32 3 MOD 4 Outlet 4 CMD With Ca...

Страница 56: ...NMP Manager The smaller the power factor less than 1 more current is needed wasted to do the same amount work M P Module port Identifier Unit Id Circuits number of circuits on unit Outlets number of unit outlets Select 1 displays current Power Factor PF and Power Threshold settings for each individual unit circuit Breaker Circuit Threshold Menu Device 1 Breaker Circuit 1 Efficiency Threshold 100 P...

Страница 57: ...NMP power factor trap if power factor is below threshold Enter threshold value Circuit Power Factor Thresholds 1 Outlet Power Factor Thresholds 2 Enter Request 1 The unit displays the number of outlets on the unit Select an outlet number to change the values for Power Factor PF Threshold and Power Threshold Outlet Circuit Threshold Menu Device 1 Outlet 1 Efficiency Threshold 100 Power Threshold 10...

Страница 58: ... factors below this value will generate an SNMP trap if enabled and power is above minimum power threshold A value of 0 disables threshold Value will be applied to all circuits and outlets MMX units Enter threshold value This option allows user to set all circuits and outlets to the same Power Threshold levels MMX refers to the metered outlet modular series Default Value 50w Minimum power required...

Страница 59: ... firmware upgrade Waiting to receive compressed image file Selecting Y for yes the unit will display the following as it waits for the firmware file At this point follow the FTP program instruction to transfer the firmware into the unit Select 2 allows the admin to upload an SSL Certificate to the unit via FTP The filename of the certificate must be ssl pem An SSL certificate is used by the unit t...

Страница 60: ...IT WILL RESET AFTER CONFIGURATION IS COMPLETE Enable Configuration File Upload Y N Waiting to receive configuration file At this point FTP the file into the unit A successful file upload and the unit will display configuration file valid updating ds62 configuration ds62 host configuration complete polling rpcs Found RPC at mod 2 port 1 rpc polling complete configuring rpcs Unsuccessful file upload...

Страница 61: ...ration file to be retrieved via ftp Enable Configuration File Retrieval Y N Select Get Current Configuration File and the unit will display A YES response and the unit will display the following var confupload file created and ready for ftp retrieval Waiting to send configuration file At this point FTP the file to your computer A Successful file retrieval and the unit displays get of configuration...

Страница 62: ...wing type Y at the prompt The unit will wait for the ASCII file to be transfer via FTP Send file in ASCII file mode Waiting for RC firmware Upgrading RC firmware on RPC at module 2 port 1 Enable update of Relay Controller firmware via Console RS232 port Enabling will reset Ethernet Module when Configuration is exited Enable Firmware Upgrade Y N y Send RC firmware file using ASCII file transfer opt...

Страница 63: ...r If still only a blinking cursor Type 5 semi colons there is a one second delay before the menu is displayed 5 You should get a Status menu similar to the one seen below ATS Series C 2014 Baytech F1 18 Option s Installed True RMS Voltage True RMS Current Internal Temperature Unit ID ATS Series Primary Source 1 Source 2 121 2 Volts Power True RMS Peak RMS True RMS Average Volt Source Current Curre...

Страница 64: ...list of commands ATS The Status Menu will display after the user logs in if a login is required This menu lists the firmware version installed options primary source secondary source voltage primary source current voltage and power and the internal temperature of the ATS unit If there are users installed on the unit a login will be required This may have a password or not It is recommended that at...

Страница 65: ...Disable Status Menu 4 Change Unit ID 5 Change Alarm Threshold 6 Change ATS Switching Voltage Points 7 Change ATS Switch Back mode time 8 Change ATS Delay Switch to secondary 9 Change Buzzer Audible Alarms X Exit Enter Request Select 1 from the configure menu to allow the admin user to add and delete users change passwords and change the outlet list The following menu appears if the unit has been r...

Страница 66: ...er NOTE If you delete the user in the first position the ATS will display the following You are deleting the current admin user The next user will become the admin user do you want to continue Y N IMPORTANT The unit must have had a power cycle or unit reset command performed recently prior to deleting the user in the first position This action will prevent the unit from having No Admin user assign...

Страница 67: ...let number s Select 3 to add all outlets to user access The unit will display Y for all outlets Select 4 to remove all outlets from a user The unit will display Y for all outlets Select 2 from the Configure Menu allows the admin user to change the names of the outlets Select this option and the unit displays all of the outlet names Default name is Outlet 1 Outlet number of outlets on unit Enter Re...

Страница 68: ...t voltage switching points The processor uses a 6 cycle window to determine if the voltage is greater than zero but less than the trip threshold This should only be set after the ATSSET command has been performed This value can be tweaked according to loading It is recommended that the default values be maintained Enter Request 7 Disable switch back to primary Y N n Current delay switch back to pr...

Страница 69: ...econdary source time is 3 Seconds Change delay switch to secondary time Y N Y Enter seconds 1 255 Enter Request 8 Disable delay switch to secondary Y N Y Enter Request Type N and press Enter The unit will display the current switch time and ask if you want to change the time Type N and press Enter and you will be sent back to the config menu Type Y and press Enter You will be asked to enter a time...

Страница 70: ...r The unit will display Y N option Type Y and press Enter to disable the Over Current Buzzer Type N and press Enter to maintain current alarm state 1 Power loss buzzer alarm Off Default off 2 Over current buzzer alarm On Default On Enter Request 2 Press Enter The unit will display Y N option Type Y and press Enter to disable the Over Current Buzzer Type N and press Enter to enable the buzzer If th...

Страница 71: ...C3 202 4 Volts Circuit C4 202 1 Volts Circuit C5 204 5 Volts Circuit C6 205 8 Volts Total kW h 0 Circuit Average Volt Group Power Amps Circuit M1 0 Watts 4 VA Circuit M2 0 Watts 4 VA Circuit M3 0 Watts 4 VA Circuit M4 0 Watts 4 VA Circuit M5 0 Watts 4 VA Circuit M6 0 Watts 4 VA Int Temp 95 9 F Ext 1 72 1 F 31 5 RH Ext 2 70 9 F Note Units with probes connected to external sensor ports will be displ...

Страница 72: ...m field length is 32 or 16 for older unit Unit ID ATS18 Type RIPSET at the outlet screen prompt to set the unit voltage The preset values are listed below The menu displays the current operating voltage and then asks the operator to choose the new operating voltage If no change is required press Enter otherwise select the appropriate number Type X to exit the RIPSET routine Current operating volta...

Страница 73: ...roduct is in excellent condition A product may not be returned after 30 days from the original date of shipment unless approved by BayTech management For additional information or more specific warranty issues contact BayTech s Technical Support or Customer Service Departments at 800 523 2702 or 228 563 7334 This warranty does not cover misuse or minor imperfections that fall within design specifi...

Страница 74: ...s Inc 5239 A Avenue Long Beach Industrial Park Long Beach MS 39560 Telephone 800 523 2702 or 228 563 7334 FAX 228 563 7335 Email support baytech net Website www baytech net Return policy refers to BayTech products purchased and returned for credit or repair A Return Authorization RA number must be obtained in all cases before returning the BayTech product Have the serial number and reason for the ...

Страница 75: ...original packaging or similar packaging The warranty does not cover damage sustained during shipment Enclose a letter with name address RA number daytime phone number and description of the problem c Mark the RA number clearly on the outside of the package d Ship the unit by insured prepaid carrier to the following address Bay Technical Associates 5239 A Avenue Long Beach Industrial Park Long Beac...

Страница 76: ...ated by the TACACS server Case 3 TACACS disabled or TACACS contact loss Enable URPC usernames as backup enabled user Log in OK URPC validates the user Case 4 TACACS disabled or TACACS contact loss Enable URPC usernames as backup disabled user Log in FAIL Neither TACACS nor the URPC can validate the user Parameters to determine if user should be able to log in TACACS enabled disabled Good Bad TACAC...

Страница 77: ...ch of the unit s side panel with two screws Verify both brackets are facing the same direction on the unit once attached M140R115 1U side panel 2U Bracket part number M140R114 Attach brackets to the each of the unit s side panel with two screws Verify both brackets are facing the same direction on the unit once attached M140RC114 U2 side panel Attach brackets and unit to rack with four screws as s...

Страница 78: ...C138 brackets to the Baytech vertical power strip In each unit locate the small bubble wrapped brackets containing two brackets and four screws See figure 1 and 2 Figure1 Figure2 Line up the bracket holes to the holes on the unit Figure 3 Figure 3 Screw in two screws Figures 4 5 6 show the bracket mounted in three different positions Figure 4 Figure 5 Figure 6 ...

Страница 79: ...e is Disabled the unit will not switch back to the Primary the alarm will light and the buzzer will sound continuously If the Switch Back Mode is enabled the unit will switch 8 seconds plus any time delay set The Default time delay is set to 0 seconds SCROLLING MENU This may occur in a Master Slave setup due to the Master unit being power up after the Slave unit and the 8 data cable connecting the...

Отзывы: