4 Operating the Salt Relax POWER
22
To access the settings, select Relay config. with
/
and confirm with
Selection of the respective relay in the individual lines is carried out using
/
.
pH primary
Only visible if pH option is installed.
Depending on the setting of the function "10 setpoint mode" in the "Service settings" menu, the pH primary
and pH secondary
are activated:
If parameter "10 setpoint mode" is set to 0 -> relay pH primary (default: PH) controls the dosing pump for
pH Minus, relay pH secondary (default Aux1) controls the dosing pump for pH Plus
If parameter "10 setpoint mode" is set to 1 -> relay pH primary (default: PH) controls the dosing pump for
pH Minus.
If parameter "10 setpoint mode" is set to 2 -> relay pH primary (default pH) controls the dosing pump for pH
Plus.
pH secondary
Only visible if pH option is installed and function "10 setpoint mode" is set to 0 in the "Service Settings"
menu.
If parameter "10 setpoint mode" in the "Service Settings" menu is set to 0, the relay pH secondary (default
Aux1) for the dosing pump pH Plus is activated.
Redox
Only visible if the redox option is installed.
The relay selected under Redox (default: Aux2) switches the additional dosing pump for disinfection if 0 is
selected in parameter "4 Electrolysis mode" in the "Service Settings" menu. In this case, the menu item
"Aux Rel 2" is not displayed in the main menu.
Setting No:
Relay Aux2 is displayed in the main menu as "Aux Rel 2" and can be freely assigned.
Heating:
Only visible if function "15 Heating" in the "Service Settings" menu is set to 1.
The relay selected under Heating (default Aux4) is activated for switching of the heating in accordance with
the settings in the menu item Filtration. The menu item Aux Rel 4 is not displayed in the main menu.
Setting No:
Relay Aux4 is visible in the main menu as "Aux Rel 4" and can be freely assigned.
Filtration:
The relay selected under Filtration (default Filter)
is activated for switching of the filtration pump in
accordance with the settings in the menu item Filtration.
Setting No:
Relay Filter is without function, the menu item Filtration is displayed in the main menu as manual ON.
Lighting
The relay selected under Lighting (default: Light) is activated for the switching of a light in accordance with
the settings in the menu item Lighting.
Setting No:
Relay Light is without function, the menu item Lighting is not displayed in the main menu.
BILD
Filtration
Heating mode