![Bayrol NATURALLY SALT Salt Relax POWER Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/bayrol/naturally-salt-salt-relax-power/naturally-salt-salt-relax-power_operating-and-installation-manual_2713062015.webp)
4 Operating the Salt Relax POWER
15
4.3.3
Auxiliary relays (Aux Rel1, Aux Rel2 Aux Rel3, Aux Rel4)
With the Salt Relax POWER, you can control up to 4 additional functions (e.g. for water attractions, counter-
current systems, garden lighting etc.). These functions are connected to the up to 4 auxiliary relays.
The following description of auxiliary relay 1 applies analogously to all further relays.
To set, select Aux Rel 1…4 with
/
and confirm with
The mode is selected in the line Mode using the
/
keys.
Manual
Allows you to switch auxiliary relay Aux1 on and off manually.
Shows whether relay Aux1 is switched on or off. Switch using the keys
/
Allows any name to be selected for relay Aux1. Use
or
to open the input field.
Automatic (time-controlled)
Up to 2 switch-on and switch-off times are defined for relay Aux1.
Use the
/
keys to access the hour for starting the selected timer. Set the hour at which the timer is
to start using
/
. Press
to enter the minutes of the starting time and set using
/
. Confirm
your entry with
or reject it with
.
The timer can also be set to switch at certain intervals (daily; every 2 days; every 3 days; every 4 days;
every 5 days; weekly; every 2 weeks; every 3 weeks; every 4 weeks). Select the desired switching
frequency using
/
.
Allows any name to be selected for relay Aux1. Use
or
to open the input field.
Temporary
When a programmable key is pressed, relay Aux1 is switched on for a defined duration (a typical use, for
example, is to activate the air jets in spas).
Runtime in minutes and a key are defined using
/
.
The key to be pressed (
or
.) is selected using
/
. Every time this key is pressed during
normal operation, the external device connected to the relay is switched on for the defined time.
Allows any name to be selected for relay Aux1. Use
or
to open the input field.
ATTENTION
The connected device will also be switched on if the programmed key is pressed by accident.
Only use this function to connect devices which do not give rise to a safety risk!
The switching of the relay is not monitored by any safety feature (e.g. flow switch)!