MX08  Multichannel System 

Technical Manual 

 
 
 
 
 
 
 

Содержание MX08

Страница 1: ...MX08 Multichannel System Technical Manual...

Страница 2: ......

Страница 3: ...3 6 Commissioning 19 4 Programming 19 4 1 Installation of xFace 19 4 2 Connection to xFace 21 4 3 N Bus Addressing via xFace 22 4 4 Gateway Setup 23 4 5 GSD GSDML EDS ESI XDD Configuration 23 4 6 Ana...

Страница 4: ...ections 70 9 3 N Bus Addressing 71 9 4 Profibus DP Setup 71 9 4 1 Profibus DP Parameters 72 9 4 2 Profibus Information 72 9 5 Profibus DP Data Structure 73 9 6 Error Table 78 9 7 Diagnostic Tests 79 1...

Страница 5: ...c Tests 118 13 MX08 EC EtherCAT Gateway 120 13 1 Front View 120 13 2 Electrical Connections 122 13 3 N Bus Addressing 123 13 4 MX08 EC Setup 123 13 4 1 EtherCAT Information 123 13 5 EtherCAT Data Stru...

Страница 6: ...would be obliged to be informed if any errors occur BAYKON cannot accept any liability for direct or indirect damages resulting from the use of this manual BAYKON reserves the right to revise this ma...

Страница 7: ...MAKING CHECKS TESTS AND ADJUSTMENTS THAT MUST BE MADE WITH POWER ON FAILING TO OBSERVE THESE PRECAUTIONS CAN RESULT IN BODILY HARM WARNING FOR CONTINUED PROTECTION AGAINST SHOCK HAZARD CONNECT TO PROP...

Страница 8: ...Sanayi B lgesi Organik Cad No 31 34956 Tepe ren Tuzla STANBUL to which this declaration relates is in conformity with the following standard s or other normative document s EC Directive Applicable Sta...

Страница 9: ...nts are mounted on the DIN rail in the control cabinet and communicate each other by internal data bus which is named N Bus The external interface is done via Gateway Gateway is slave in the field bus...

Страница 10: ...D Analog Digitizer It converts the low level strain gage load cell analog signal to high resolution and accurate digital signal Its programmability for bipolar input signal gives the instrument advant...

Страница 11: ...daptive filter Weighing functions Taring zeroing auto zero tracking motion detection auto zero at power up save tare at power off increased resolution Linearity Within 0 0015 FS 2 ppm C Load cells Exc...

Страница 12: ...HCP or manual IP assign over xFace or Anybus Ipconfig Device identity customization Topology Line Bus Star or Tree topology depending on physical media Installation Switched Ethernet transmission with...

Страница 13: ...d Topology Line Tree Star or Daisy chain topology depending on physical media Installation Switched Ethernet transmission with shielded twisted pair cables and RJ 45 connectors Isolation Galvanically...

Страница 14: ...24 VDC max 100 mA Environment and Enclosure Operation temp 10 C to 40 C 85 RH max non condensing Enclosure Polyamide mounting in standard DIN rails IP20 MX08 DP Display Conversion rate 4 refresh per s...

Страница 15: ...sings are IP20 polyamide and easily mounting on NS 37 7 or NS 35 15 standard DIN rail Drawings of the housing are seen below 22 5 mm 45 mm 99 mm 114 5 mm View A View B Side view MX08 AD MX08 IO MX08 M...

Страница 16: ...2 2 2 2 2 2 2 2 3 pos and 3 81mm pitch green plug for RS 232C or RS 485 2 1 1 1 1 1 1 7 pos and 3 81mm pitch black plug for load cell cable 1 5 pos and 3 81mm pitch green plug for inputs 1 8 pos and...

Страница 17: ...st the electromagnetic disturbances Load cell cable trays must be separated from others if possible If there are noise generating equipments such as heavy load switches motor control equipments induct...

Страница 18: ...uired electrical connections should be done as described below 3 3 1 Power Supply and Grounding Power supply voltage of the instrument shall be between 12 VDC and 28 VDC The current resumption of the...

Страница 19: ...0 seconds Warning Do not forget to connect the grounding pin to the reference ground 3 3 2 Load Cell Connector To avoid damages the load cell wiring should be made carefully before energizing the inst...

Страница 20: ...ng for programming the system and for other purposes described in the related gateway section RS 232C Serial interface Specifications Usage Programming and calibration xFace Interfacing with PC or PLC...

Страница 21: ...ON Please read this manual carefully before energizing the instrument Perform the commissioning operation according the procedure given in Section 2 6 Only trained person is allowed for cleaning commi...

Страница 22: ...shall be written with Latin characters Chinese folder name is not supported Figure 3 2 xFace installation step 2 If the Version Conflict window is displayed click to No to All button Figure 3 3 xFace...

Страница 23: ...nning xFace select the instrument model you use Select PC com port at connection settings menu in the tools tab and click the connect icon The traffic lights of connect icon turns from red to green li...

Страница 24: ...nd Addressing tabs becomes active First address the instruments to N Bus to activate the instruments in MX08 system Addressing Analog Digitizers to N Bus First click Read button to read the N MAC numb...

Страница 25: ...ions of Gateway instrument Active Digitizer This block indicates the active Analog Digitizers and their N Bus address in the system For more information refer to Section 4 Active I O This block indica...

Страница 26: ...ull system GSD configuration Clicking GSD GSDML Configuration in Tool menu opens the below window Select quantity of MX08 AD and MX08 IO in your system and click to Write new GSD GSDML file This prope...

Страница 27: ...or right arrows selects the current Analog Digitizer Analog Digitizer Parameters Refer to Section 4 3 1 for details Description This block helps to user to explain the parameters Read from Digitizer C...

Страница 28: ...without test weights Calibration coefficients Figure 3 12 Calibration You can find programming and calibration descriptions in Section 4 3 4 7 Analog Digitizer Performance Testing MX08 AD performance...

Страница 29: ...sed to N Bus One way is addressing by xFace and it is described above Another way is addressing via programming switch up to 7 First energize the instruments installed on the N Bus Press programming s...

Страница 30: ...ess numbers of N Bus slave instruments are recommended 4 10 Back up Parameters and Calibration The parameter settings and calibration coefficients can be saved to the back up file after reading these...

Страница 31: ...ar is address byte of N Bus slave instrument 5 N Bus master instrument s address byte is default 1 for RS 232C and Ethernet interfaces Command format A general description of the command is the follow...

Страница 32: ...iately after receiving the command B Read Gross weight Command ADR B Response ADR B STATUS SIGN WEIGHT VALUE Example Command 12B Response 12BS 000123 4 gross weight is stable and 123 4 12BD 000123 4 g...

Страница 33: ...tus and it must be stable Else Nack status is send There is no time duration for stability checking Status can be Stable or Nack S Read Status Command ADR S Response ADR S STATUS 1 STATUS 2 STATUS 3 E...

Страница 34: ...mmand ADR V Response ADR V A Outputs Example Command 12V Response 12VA3 Output 2 and Output 1 are active 12VA4296 Output 15 10 8 5 3 2 are active 12VAFF All 8 outputs are active 12VN Could not read ou...

Страница 35: ...st be in zeroing range for all operating modes Status must be stable in 2 seconds time out delay If so Ack is send If it can not be stable in time out delay Nack is send CHK is transmitted as two ASCI...

Страница 36: ...in operation The programming switch on front panel of the instrument is used for N Bus addressing without PC Refer to Section 3 9 and for diagnostic tests refer to Section 4 6 The operation mode of th...

Страница 37: ...ond Refer to the error table in Section 4 5 Table 4 1 Annunciater LEDs 5 2 Electrical Connection Load cell Connection To avoid damages the load cell wiring should be made carefully before energizing t...

Страница 38: ...for better weighing performance 5 3 1 Setup the Scale Parameters In setup menu parameter values at MX08 AD can be seen changed and saved to MX08 AD These parameters are Increased External Resolution T...

Страница 39: ...of the scale capacity are Disable 2 10 This parameter must be disabled or carefully programmed at the silo weighing tank weighing or automatic weighing applications for preventing unwanted zeroing at...

Страница 40: ...ment Not available in Count Mode Default is Enable Save Tare at Power Off If this function is enabled tare value is stored at power off and instrument starts up in Net mode at power on Not available i...

Страница 41: ...l range If you select the count mode there is no scale build and instrument calibration Each MX08 AD instrument is adjusted in production to increase the calibration accuracy MX08 AD input signal rang...

Страница 42: ...o calibration the scale must be stable Approximately 5 seconds later the span calibration window is displayed Load the scale and enter the loaded test weight value then click OK button The scale must...

Страница 43: ...emporary zero If the scale is stable press Yes button The WAIT message appears on the virtual display approximately for 5 seconds to determine temporary zero Then the span calibration window is displa...

Страница 44: ...igitizer these data transferred to the instrument and eCal is finalized If the scale is empty and you want to make automatic zero adjustment instead of entering estimated dead load press eCal with Zer...

Страница 45: ...oard Over Load Check the load Load cell or instrument could be defective Weight is too low ADC Out Input signal outside the input range Check the load Check the calibration Load cell or instrument cou...

Страница 46: ...the instrument The instrument will go in to the Load cell Signal test mode which is indicated by status of LEDs as seen below Test LED s Status Description Err Load cell signal LED blanks while load c...

Страница 47: ...ayed Also installed Analog Digitizers on the N Bus are indicated with N Bus address information Two keys are used for selecting Analog Digitizer to display weight or count data 6 1 Front View Model na...

Страница 48: ...t digit does not display and Pwr LED blanks For example If the weight data is 123 010 Pwr LED blanks and 23010 is displayed In count mode data is displayed on the display without least significant dig...

Страница 49: ...e N Bus Communication Error Re address the instruments on N Bus Refer to section 3 3 or Section 3 9 N Bus addressing Check the Gateway instrument whether it is in system and powered on Check the N Bus...

Страница 50: ...mands 7 1 Front View There are 3 annunciater LEDs on front panel to show the instrument status in operation The programming switch on front panel of the instrument is used for N Bus addressing without...

Страница 51: ...d Err Error No Error found Error Look at the error table in Section 6 4 Blank Light Flash Blank for 0 3 second Refer to the error table in Section 6 4 Table 6 1 Annunciater LEDs 7 2 Electrical Connect...

Страница 52: ...and wait at least for 30 seconds Warning Connect the grounding terminal to the reference ground 24V 0V Figure 6 3 Pin layout of MX08 IO 24 VDC connector 7 3 MX08 IO Status MX08 IO instruments are fol...

Страница 53: ...the LEDs located on the front panel Then try to solve the problem according to the error table given below Error Code Description Actions to take Possible cause Pwr Link Err System Error Re energize t...

Страница 54: ...he instrument status in operation The programming switch on front panel of the instrument is used for N Bus addressing without PC refer to Section 3 9 and for diagnostic tests refer to Section 7 7 The...

Страница 55: ...7 6 Blank Light Flash Blank for 0 3 second Table 7 1 Annunciater LEDs 8 2 Electrical Connection RS 485 and RS 232C and power supply terminals pin configurations are shown in Figure 7 2 Figure 7 2 MX0...

Страница 56: ...the safety of your measuring system Before interfering the instrument please turn off the power and wait at least for 30 seconds Warning Connect the grounding terminal to the reference ground 24V 0V F...

Страница 57: ...a slave Refer to Refer to Section 3 11 for details Modbus RTU High Low Modbus RTU communication Refer to Section 7 5 for details Modbus RTU Low High Modbus RTU communication Refer to Section 7 5 for...

Страница 58: ...transmitted Select disable if this port is not used BSI Communicates in BSI data format as a slave Refer to Refer to Section 3 11 for details Modbus RTU High Low Modbus RTU communication Refer to Sec...

Страница 59: ...RTU data format Immediate Modbus RTU Answer is sent immediately after Request is received 20 msec Modbus RTU Answer is delayed 20 msec after Request is received This property is very helpful for slow...

Страница 60: ...s information in the web site of http www modbus org Examples Performing Read and Write operations according Modbus RTU High Low to hex system with the MX08 MB set to address 0x01 Indicated value of M...

Страница 61: ...0 01 79 84 MX08 AD 0 is in ready status zero calibration can be performed Request 01 10 04 63 00 01 02 00 BC EB B2 Zero calibration command Answer 01 10 00 6D 00 01 90 14 Request 01 03 04 66 00 01 65...

Страница 62: ...Power supply is not in required voltage range 7 No instrument found 40004 R 2 Tare Weight 40006 R 2 Gross Weight 40008 R 1 Status Motion Net mode Data ok image of register 40003 40009 R W 1 Control 0...

Страница 63: ...Bipolar 2 Force Mode Unipolar 3 Force Mode Bipolar 4 Weight Mode Unipolar 40015 R W 1 Operation mV of Count Mode 0 5 mV 1 10 mV 2 15 mV 3 18 mV 40016 R W 1 Digital Filters 0 Fast 9 Slow 40034 R 1 Volt...

Страница 64: ...8I is active 11 0 addressed 8O is active D1 D2 IO 1 00 1 addressed no instrument found 01 1 addressed 4I 4O is active 10 1 addressed 8I is active 11 1 addressed 8O is active D3 D4 IO 2 00 2 addressed...

Страница 65: ...R 2 MX08 AD 0 Indicated Weight 41008 R 2 MX08 AD 0 Gross Weight 41010 R 2 MX08 AD 0 Tare Weight 41012 R 1 MX08 AD 1 Status 41013 R 2 MX08 AD 1 Indicated Weight 41015 R 2 MX08 AD 1 Gross Weight 41017...

Страница 66: ...4 Input 4 Output 8 Input 8 Output D0 Input 1 Input 1 D1 Input 2 Input 2 D2 Input 3 Input 3 D3 Input 4 Input 4 D4 Input 5 D5 Input 6 D6 Input 7 D7 Input 8 D8 Output 1 Output 1 D9 Output 2 Output 2 D10...

Страница 67: ...ight Stable 1 Unstable D12 0 Out of Zero R 1 In Zero Range MX08 AD 6 D13 0 Weight Stable 1 Unstable D14 0 Out of Zero R 1 In Zero Range MX08 AD 7 D15 0 Weight Stable 1 Unstable 41106 R 1 All MX08 AD S...

Страница 68: ...ssages shown by the LEDs located on the front panel Then try to solve the problem according to the error table given below Error Code Description Actions to take Possible cause Pwr Link Err System Err...

Страница 69: ...LED s Status Description Pwr Lnk Err RS 232C RxD Pwr LED blanks 0 3 sec after receiving any data Press programming switch to go next test RS 232C TxD A to Z characters are send sequentially in 0 8 s...

Страница 70: ...e 3 annunciater LEDs on front panel to show the instrument status in operation The programming switch on front panel of the instrument is used for N Bus addressing without PC refer to Section 3 9 and...

Страница 71: ...6 Blank Light Flash Blank for 0 3 second Table 8 1 Annunciater LEDs ST Status LED State Indication Comment Off Not power or not initialized No power or profibus module is in initialization state Gree...

Страница 72: ...ound Figure 8 2 MX08 PB serial interface connections RS 232C Serial interface Usage Used for service port xFace Baud rate 9600 bps Length and parity 8 bit no parity Start Stop bits 1 start bit and 1st...

Страница 73: ...Connector 9 3 N Bus Addressing MX08 instruments communicate each other over internal data bus which is called N Bus MX08 gateway instrument is master of N Bus All other instruments are slave and shall...

Страница 74: ...ace Gateway information block in Gateway tab allows the user to know much information about gateway instrument as in the following Field bus Profibus DP Firmware Version Revision number of firmware Fi...

Страница 75: ...strument found 1 7 addressed MX08 AD is active Active AD instruments D22 0 No instrument found 1 6 addressed MX08 AD is active D21 0 No instrument found 1 5 addressed MX08 AD is active D20 0 No instru...

Страница 76: ...trument does not found Error Codes of Digitizer 0110 Low High voltage detection error 0101 In programming mode 0100 System Error 0011 ADC under 0010 ADC over 0001 ADC out 0000 No error found D11 D10 N...

Страница 77: ...until scale become stable Check grounding wiring D7 D6 D5 D4 D3 D2 D1 D0 0000 1001 Calibration Errors Calibration Process Status 0000 0100 Span calibration in process 0000 0011 Zero calibration in pro...

Страница 78: ...mand I O Write Control 1 Input Outputs are change over Common Command List below 1001 RESET 1000 SET Outputs D7 D6 D5 D4 0000 None Common Command List 0001 Zeroing command sent to all Digitizers 0010...

Страница 79: ...ght Description of 2 nd Dword R 00001 Gross weight 00010 Tare weight 00011 Indicated weight floating point type 00100 Gross weight floating point type 00101 Tare weight floating point type 10000 Calib...

Страница 80: ...ssages shown by the LEDs located on the front panel Then try to solve the problem according to the error table given below Error Code Description Actions to take Possible cause Pwr Link Err System Err...

Страница 81: ...the test result as described below You can go to the next test by pressing the programming switch Test LED s Status Description Pwr Lnk Err RS 232C RxD Pwr LED blanks 0 3 sec after receiving any data...

Страница 82: ...e 3 annunciater LEDs on front panel to show the instrument status in operation The programming switch on front panel of the instrument is used for N Bus addressing without PC Refer to Section 3 9 and...

Страница 83: ...ower or not initialized No power or profinet module is in initialization state Green Initialized Green 1 flash Initialized diagnostic event s present Diagnostic is active Red Exception error There is...

Страница 84: ...Profinet interface Usage Profinet interface with PC or PLC Data formats Profinet Ethernet The Ethernet interface operates at 100Mbit full duplex as required by PROFINET Warning Connect the shield to t...

Страница 85: ...addressed to gateway N Bus addressing can be done by using xFace PC software Refer to Section 3 3 or via programming switch Section 3 9 10 4 MX08 PN Setup MX08 gateway set up is done by xFace software...

Страница 86: ...If DHCP is disabled obtain primary DNS manually Default is 208 67 222 222 Secondary DNS If DHCP is disabled obtain secondary DNS manually Default is 208 67 220 220 Host Name Enter a unique host name...

Страница 87: ...trument found 1 7 addressed MX08 AD is active Active AD instruments D22 0 No instrument found 1 6 addressed MX08 AD is active D21 0 No instrument found 1 5 addressed MX08 AD is active D20 0 No instrum...

Страница 88: ...trument does not found Error Codes of Digitizer 0110 Low High voltage detection error 0101 In programming mode 0100 System Error 0011 ADC under 0010 ADC over 0001 ADC out 0000 No error found D11 D10 N...

Страница 89: ...until scale become stable Check grounding wiring D7 D6 D5 D4 D3 D2 D1 D0 0000 1001 Calibration Errors Calibration Process Status 0000 0100 Span calibration in process 0000 0011 Zero calibration in pro...

Страница 90: ...mand I O Write Control 1 Input Outputs are change over Common Command List below 1001 RESET 1000 SET Outputs D7 D6 D5 D4 0000 None Common Command List 0001 Zeroing command sent to all Digitizers 0010...

Страница 91: ...ght Description of 2 nd Dword R 00001 Gross weight 00010 Tare weight 00011 Indicated weight floating point type 00100 Gross weight floating point type 00101 Tare weight floating point type 10000 Calib...

Страница 92: ...essages shown by the LEDs located on the front panel Then try to solve the problem according to the error table given below Error Code Description Actions to take Possible cause Pwr Link Err System Er...

Страница 93: ...the test result as described below You can go to the next test by pressing the programming switch Test LED s Status Description Pwr Lnk Err RS 232C RxD Pwr LED blanks 0 3 sec after receiving any data...

Страница 94: ...strument status in operation The programming switch on front panel of the instrument is used for N Bus addressing without PC refer to Section 3 9 and for diagnostic tests refer to Section 10 7 The sta...

Страница 95: ...1 Annunciater LEDs 11 2 Electrical Connections Ethernet and RS 232C and power supply terminals are shown in Figure 10 1 Ethernet Connector RJ45 Pin Signal Direction Description 1 TX Out Differential E...

Страница 96: ...ace with PC or PLC Data formats BSI Modbus TCP IP High Low Modbus TCP IP Low High Ethernet The Ethernet interface operates at 10 Mbit half duplex Warning Connect the shield to the reference ground or...

Страница 97: ...addressed to gateway N Bus addressing can be done by using xFace PC software Refer to Section 3 3 or via programming switch Section 3 9 11 4 MX08 EN Setup MX08 gateway set up is done by xFace software...

Страница 98: ...if it is not used to increase the interfacing performance Default is BSI RS 232C Checksum The checksum can be enabled or disabled from BSI data format The checksum calculation can be found in the rel...

Страница 99: ...n the related data format description Default is Enable 11 4 2 Ethernet Parameters on EtherX There are 11 parameters for Ethernet network Host Name Device name of the instrument Default is IP Address...

Страница 100: ...cant word is stored to the lowest register address and most significant word is stored to the highest register address Write operations can only be done to the allowed registers And they are indicated...

Страница 101: ...D 0 is tared Taring MX08 AD 1 at register 41063 Request 10 04 26 00 01 02 00 02 Answer 10 04 26 00 01 MX08 AD 1 is tared Zero Calibration of MX08 AD 0 Request 03 04 66 00 01 Read status it must be in...

Страница 102: ...Data ok D2 0 Weight Stable 1 Weight unstable D3 0 Gross Mode 1 Net mode D4 Not in use D5 0 Weight Force 1 Count Mode D6 D11 Not in use D12 0 Out of zero range 1 Weight is in zero range D13 D14 D15 Er...

Страница 103: ...very low or too high 35 Calibration Error Calibration test weight is not enough Increase calibration weight value 40011 Check load cell connections 37 Scale unstable Wait until scale becomes stable C...

Страница 104: ...ument found 01 1 addressed 4I 4O is active 10 1 addressed 8I is active 11 1 addressed 8O is active D3 D4 IO 2 00 2 addressed no instrument found 01 2 addressed 4I 4O is active 10 2 addressed 8I is act...

Страница 105: ...ht 41008 R 2 MX08 AD 0 Gross Weight 41010 R 2 MX08 AD 0 Tare Weight 41012 R 1 MX08 AD 1 Status 41013 R 2 MX08 AD 1 Indicated Weight 41015 R 2 MX08 AD 1 Gross Weight 41017 R 2 MX08 AD 1 Tare Weight 410...

Страница 106: ...70 W 1 Not used 41071 R W 1 MX08 IO 0 I O Control 4 Input 4 Output 8 Input 8 Output D0 Input 1 Input 1 D1 Input 2 Input 2 D2 Input 3 Input 3 D3 Input 4 Input 4 D4 Input 5 D5 Input 6 D6 Input 7 D7 Inpu...

Страница 107: ...In Zero Range MX08 AD 5 D11 0 Weight Stable 1 Unstable D12 0 Out of Zero R 1 In Zero Range MX08 AD 6 D13 0 Weight Stable 1 Unstable D14 0 Out of Zero R 1 In Zero Range MX08 AD 7 D15 0 Weight Stable 1...

Страница 108: ...essages shown by the LEDs located on the front panel Then try to solve the problem according to the error table given below Error Code Description Actions to take Possible cause Pwr Link Err System Er...

Страница 109: ...the test result as described below You can go to the next test by pressing the programming switch Test LED s Status Description Pwr Lnk Err RS 232C RxD Pwr LED blanks 0 3 sec after receiving any data...

Страница 110: ...ere are 3 annunciater LEDs on front panel to show the instrument status in operation The programming switch on front panel of the instrument is used for N Bus addressing without PC Refer to Section 3...

Страница 111: ...0 3 second Table 11 1 Annunciater LEDs MS Module Status LED LED State Description Off No power Green Controlled by a scanner in run state Green flashing Not configured or scanner in idle state Red Maj...

Страница 112: ...owerlink interface Usage EtherNet IP interface with PC or PLC Data formats EtherNet IP Ethernet The Ethernet interface operates at 100Mbit half duplex as required by EtherNet IP Warning Connect the sh...

Страница 113: ...tware Refer to Section 3 3 or via programming switch Section 3 9 12 4 MX08 EI Setup MX08 gateway set up is done by xFace software as described in this section Connect MX08 EI instrument to your PC via...

Страница 114: ...ion Revision number of firmware Firmware Date Generated firmware date Hardware Version Revision number of main pcb board Serial Number Instrument s serial number Gateway Status Follow the status wheth...

Страница 115: ...nstrument found 1 7 addressed MX08 AD is active Active AD instruments D22 0 No instrument found 1 6 addressed MX08 AD is active D21 0 No instrument found 1 5 addressed MX08 AD is active D20 0 No instr...

Страница 116: ...strument does not found Error Codes of Digitizer 0110 Low High voltage detection error 0101 In programming mode 0100 System Error 0011 ADC under 0010 ADC over 0001 ADC out 0000 No error found D11 D10...

Страница 117: ...until scale become stable Check grounding wiring D7 D6 D5 D4 D3 D2 D1 D0 0000 1001 Calibration Errors Calibration Process Status 0000 0100 Span calibration in process 0000 0011 Zero calibration in pro...

Страница 118: ...mand I O Write Control 1 Input Outputs are change over Common Command List below 1001 RESET 1000 SET Outputs D7 D6 D5 D4 0000 None Common Command List 0001 Zeroing command sent to all Digitizers 0010...

Страница 119: ...ght Description of 2 nd Dword R 00001 Gross weight 00010 Tare weight 00011 Indicated weight floating point type 00100 Gross weight floating point type 00101 Tare weight floating point type 10000 Calib...

Страница 120: ...the N BUS connector whether they are installed on the rail Blank Light Flash Blank for 0 3 second Table 11 2 Error table 12 7 Diagnostic Tests RC 232C serial interface test can be performed sequential...

Страница 121: ...al Manual Rev 2 5 Page 119 of 144 If you short circuit RXD and TXD pins on RS 232C port and go in to TxD test the receiving data is shown by Pwr LED Press programming switch for 5 seconds to exit diag...

Страница 122: ...e 3 annunciater LEDs on front panel to show the instrument status in operation The programming switch on front panel of the instrument is used for N Bus addressing without PC Refer to Section 3 9 and...

Страница 123: ...second Table 12 1 Annunciater LEDs RUN LED LED State Description Off INIT Green OPERATIONAL Green blinking PRE OPERATIONAL Green single flash SAFE OPERATIONAL Red Fatal Event LINK Activity LED LED Sta...

Страница 124: ...CAT interface with PC or PLC Data formats EtherCAT Ethernet The Ethernet interface operates at 100Mbit full duplex as required by EtherCAT Warning Connect the shield to the reference ground or shield...

Страница 125: ...software Refer to Section 3 3 or via programming switch Section 3 9 13 4 MX08 EC Setup MX08 gateway set up is done by xFace software as described in this section Connect MX08 EC instrument to your PC...

Страница 126: ...n Revision number of firmware Firmware Date Generated firmware date Hardware Version Revision number of main pcb board Serial Number Instrument s serial number Gateway Status Follow the status whether...

Страница 127: ...strument found 1 7 addressed MX08 AD is active Active AD instruments D22 0 No instrument found 1 6 addressed MX08 AD is active D21 0 No instrument found 1 5 addressed MX08 AD is active D20 0 No instru...

Страница 128: ...strument does not found Error Codes of Digitizer 0110 Low High voltage detection error 0101 In programming mode 0100 System Error 0011 ADC under 0010 ADC over 0001 ADC out 0000 No error found D11 D10...

Страница 129: ...until scale become stable Check grounding wiring D7 D6 D5 D4 D3 D2 D1 D0 0000 1001 Calibration Errors Calibration Process Status 0000 0100 Span calibration in process 0000 0011 Zero calibration in pro...

Страница 130: ...mand I O Write Control 1 Input Outputs are change over Common Command List below 1001 RESET 1000 SET Outputs D7 D6 D5 D4 0000 None Common Command List 0001 Zeroing command sent to all Digitizers 0010...

Страница 131: ...ght Description of 2 nd Dword R 00001 Gross weight 00010 Tare weight 00011 Indicated weight floating point type 00100 Gross weight floating point type 00101 Tare weight floating point type 10000 Calib...

Страница 132: ...the N BUS connector whether they are installed on the rail Blank Light Flash Blank for 0 3 second Table 12 2 Error table 13 7 Diagnostic Tests RC 232C serial interface test can be performed sequential...

Страница 133: ...al Manual Rev 2 5 Page 131 of 144 If you short circuit RXD and TXD pins on RS 232C port and go in to TxD test the receiving data is shown by Pwr LED Press programming switch for 5 seconds to exit diag...

Страница 134: ...re 3 annunciater LEDs on front panel to show the instrument status in operation The programming switch on front panel of the instrument is used for N Bus addressing without PC Refer to Section 3 9 and...

Страница 135: ...g or not active Green fast flashinga NMT_CS_BASIC_ETHERNET Basic Ethernet state no POWERLINK traffic has been detected Green single flash NMT_CS_PRE_OPERATIONAL_1 Only asynchronous data Green double f...

Страница 136: ...LED State Description Off No error Red If the STATUS LED is not red a non fatal error has been detected If the STATUS LED is red a fatal event was encountered 14 2 Electrical Connections Powerlink RS...

Страница 137: ...ait at least for 30 seconds Warning Connect the grounding terminal to the reference ground 24V 0V Figure 13 3 Pin layout of MX08 PL 24 VDC connector 14 3 N Bus Addressing MX08 instruments communicate...

Страница 138: ...uch information about gateway instrument as in the following Field bus Powerlink Firmware Version Revision number of firmware Firmware Date Generated firmware date Hardware Version Revision number of...

Страница 139: ...strument found 1 7 addressed MX08 AD is active Active AD instruments D22 0 No instrument found 1 6 addressed MX08 AD is active D21 0 No instrument found 1 5 addressed MX08 AD is active D20 0 No instru...

Страница 140: ...strument does not found Error Codes of Digitizer 0110 Low High voltage detection error 0101 In programming mode 0100 System Error 0011 ADC under 0010 ADC over 0001 ADC out 0000 No error found D11 D10...

Страница 141: ...until scale become stable Check grounding wiring D7 D6 D5 D4 D3 D2 D1 D0 0000 1001 Calibration Errors Calibration Process Status 0000 0100 Span calibration in process 0000 0011 Zero calibration in pro...

Страница 142: ...mand I O Write Control 1 Input Outputs are change over Common Command List below 1001 RESET 1000 SET Outputs D7 D6 D5 D4 0000 None Common Command List 0001 Zeroing command sent to all Digitizers 0010...

Страница 143: ...ght Description of 2 nd Dword R 00001 Gross weight 00010 Tare weight 00011 Indicated weight floating point type 00100 Gross weight floating point type 00101 Tare weight floating point type 10000 Calib...

Страница 144: ...the N BUS connector whether they are installed on the rail Blank Light Flash Blank for 0 3 second Table 13 2 Error table 14 7 Diagnostic Tests RC 232C serial interface test can be performed sequential...

Страница 145: ...al Manual Rev 2 5 Page 143 of 144 If you short circuit RXD and TXD pins on RS 232C port and go in to TxD test the receiving data is shown by Pwr LED Press programming switch for 5 seconds to exit diag...

Страница 146: ...onnection Setting menu How can I solve that problem Answer Another software may be connected to that COM port Close all applications before running xFace Question My PC could not interface with MX08 H...

Страница 147: ......

Страница 148: ...BAYKON A Kimya Sanayicileri Organize Sanayi B lgesi Organik Cad No 31 Tepe ren 34956 stanbul TURKEY Tel 0216 593 26 30 pbx Fax 0216 593 26 38 e mail baykonservis baykon com http www baykon com...