Section 15 - Zone Response Type Definitions
15–3
Type 10
Interior w/Delay
This zone type gives Entry Delay (using the programmed entry
time) if it is tripped when the panel is armed in the AWAY mode.
Entry Delay begins whenever sensors in this zone are violated,
regardless of whether or not an Entry/Exit Delay zone was tripped
first.
No Entry Delay
is provided if the zone is tripped when the
panel is armed in the MAXIMUM mode.
Exit
Delay is present for
any
arming mode.
This zone type is bypassed when the panel
is armed in the STAY or INSTANT mode.
Type 20
Arm-STAY
This is a special-purpose zone type used with 5800 Series Wireless
Pushbutton units, which arms the system in the STAY mode when
the zone is activated. Pushbutton units send zone number as a user
number to the Central Station when arming or disarming.
Type 21
Arm-AWAY
This is a special-purpose zone type used with 5800 Series wireless
pushbutton units, which arms the system in the AWAY mode when
the zone is activated. Pushbutton units send the zone number as a
user number to the Central Station when arming or disarming.
Type 22
Disarm
This is a special-purpose zone type used with 5800 Series wireless
pushbutton units, which disarms the system when the zone is
activated.
Type 23
No Alarm Response
This zone type can be used on a zone when an output relay action is
desired, but with no accompanying alarm (for example, lobby door
access).
Type 24
Silent Burglary
This zone type provides an instant alarm, with NO audible
indication at any keypad or external sounder, if the zone is faulted
when the system is armed in the AWAY, STAY, INSTANT, or
MAXIMUM mode. This zone type is usually assigned to all sensors
or contacts on exterior doors and windows where bells and/or sirens
are NOT desired. A report is sent to the Central Station.
NOTE:
All of the zone types described are available for the wireless portion of the system, if
used.
Содержание Vista-20Bay
Страница 2: ......
Страница 22: ...VISTA 20BAY Installation Setup Guide 3 4 ...
Страница 28: ...VISTA 20BAY Installation Setup Guide 4 6 ...
Страница 32: ...VISTA 20BAY Installation Setup Guide 5 4 ...
Страница 40: ...VISTA 20BAY Installation Setup Guide 6 8 ...
Страница 64: ...VISTA 20BAY Installation Setup Guide 14 4 ...
Страница 68: ...VISTA 20BAY Installation Setup Guide 15 4 ...
Страница 82: ...VISTA 20BAY Installation Setup Guide 16 14 ...
Страница 92: ...VISTA 20BAY Installation Setup Guide 17 10 ...
Страница 98: ...VISTA 20BAY Installation Setup Guide 18 6 ...
Страница 100: ...VISTA 20BAY Installation Setup Guide 19 2 ...
Страница 110: ...VISTA 20BAY Installation Setup Guide 22 4 ...
Страница 116: ...VISTA 20BAY Installation Setup Guide 23 6 ...
Страница 122: ...VISTA 20BAY Installation Setup Guide 25 4 NOTES ...
Страница 128: ...VISTA 20BAY Installation Setup Guide A 2 ...
Страница 130: ...VISTA 20BAY Installation Setup Guide B 2 ...
Страница 138: ... 1 9 l N7526 4V1 5 00 SINCE 1946 BAY ALARM 925 Ygnacio Valley Road Walnut Creek CA 94596 ...