26–1
S E C T I O N 2 6
Specifications & Accessories
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section
♦
Specifications
♦
Accessories
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Specifications
VISTA-20BAY
SECURITY CONTROL
1. Physical:
12-1/2” W x 14-1/2” H x 3” D (318mm x 368mm x 76mm)
2. Electrical:
Powerline Carrier device Interface AC Transformer
VOLTAGE INPUT:
16.5VAC from plug-in 25VA transformer, ADEMCO No. 1321
(in USA)
RECHARGEABLE
BACKUP BATTERY:
12VDC, 4AH
-
17.2AH (Sealed Lead Acid). Refer to
Section 13:
Final Power-Up
to calculate the actual battery size needed.
Charging Voltage: 13.8VDC.
ALARM SOUNDER:
12V, 2.0 Amp output can drive 12V BELLS or can drive one or
two 702 (
series
-connected) self-contained 20-watt sirens. Do
not
connect two 702s in parallel.
AUXILIARY POWER
OUTPUT:
12VDC, 600mA max (500mA max for UL installations).
Interrupts for 4-wire smoke detector reset.
Note
: For UL installations, Alarm Sounder plus Auxiliary Power currents should not
exceed 600mA total.
STANDBY TIME:
(see Table in
Section 13: Final Power-Up)
FUSE:
Battery (3A) No. 90–12
3. Communication:
FORMATS
SUPPORTED:
ADEMCO Express:
10 characters/sec, DTMF (TouchTone) Data Tones,
1400/2300Hz ACK, 1400Hz KISSOFF.
ADEMCO Contact
ID Reporting:
10 characters/sec., DTMF (TouchTone) Data Tones,
1400/2300Hz ACK, 1400Hz KISSOFF.
ADEMCO Low
Speed:
10 pulses/sec, 1900Hz Data Tone, 1400Hz ACK/KISSOFF.
Radionics/SESCOA:
20 pulses/sec, 1800Hz Data Tone, 2300Hz ACK/KISSOFF. Can
report 0-9, B-F.
Line Seize: Double Pole
Ringer Equivalence: 0.7B
FCC Registration No.: AC 398U–68192–AL–E
4. Maximum Zone
Resistance:
Zones 1-8 = 300 ohms excluding EOLR
Содержание Vista-20Bay
Страница 2: ......
Страница 22: ...VISTA 20BAY Installation Setup Guide 3 4 ...
Страница 28: ...VISTA 20BAY Installation Setup Guide 4 6 ...
Страница 32: ...VISTA 20BAY Installation Setup Guide 5 4 ...
Страница 40: ...VISTA 20BAY Installation Setup Guide 6 8 ...
Страница 64: ...VISTA 20BAY Installation Setup Guide 14 4 ...
Страница 68: ...VISTA 20BAY Installation Setup Guide 15 4 ...
Страница 82: ...VISTA 20BAY Installation Setup Guide 16 14 ...
Страница 92: ...VISTA 20BAY Installation Setup Guide 17 10 ...
Страница 98: ...VISTA 20BAY Installation Setup Guide 18 6 ...
Страница 100: ...VISTA 20BAY Installation Setup Guide 19 2 ...
Страница 110: ...VISTA 20BAY Installation Setup Guide 22 4 ...
Страница 116: ...VISTA 20BAY Installation Setup Guide 23 6 ...
Страница 122: ...VISTA 20BAY Installation Setup Guide 25 4 NOTES ...
Страница 128: ...VISTA 20BAY Installation Setup Guide A 2 ...
Страница 130: ...VISTA 20BAY Installation Setup Guide B 2 ...
Страница 138: ... 1 9 l N7526 4V1 5 00 SINCE 1946 BAY ALARM 925 Ygnacio Valley Road Walnut Creek CA 94596 ...