RECOMMENDATIONS FOR PROPER PROTECTION
The Following Recommendations For The Location Of Fire And Burglary Detection
Devices Help Provide Proper Coverage For The Protected Premises.
Recommendations for Smoke and Heat Detectors
With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations
contained in the National Fire Protection Association's (NFPA) Standard #72 noted below.
Early-warning fire detection is best achieved by the installation of fire detection equipment in all rooms
and areas of the household as follows: For minimum protection, a smoke detector should be installed
outside of each separate sleeping area, and on each additional floor of a multi-floor family living unit,
including basements. The installation of smoke detectors in kitchens, attics (finished or unfinished), or in
garages is not normally recommended.
For additional protection the NFPA recommends that you install heat or smoke detectors in the living
room, dining room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility and storage rooms,
basements and attached garages.
In addition, we recommend the following:
• Install a smoke detector inside every bedroom where a smoker sleeps.
• Install a smoke detector inside every bedroom where someone sleeps with the door partly or
completely closed. Smoke could be blocked by the closed door. Also, an alarm in the hallway outside
may not wake up the sleeper if the door is closed.
• Install a smoke detector inside bedrooms where electrical appliances (such as portable heaters, air
conditioners or humidifiers) are used.
• Install a smoke detector at both ends of a hallway if the hallway is more than 40 feet (12 meters) long.
• Install smoke detectors in any room where an alarm control is located, or in any room where alarm
control connections to an AC source or phone lines are made. If detectors are not so located, a fire
within the room could prevent the control from reporting a fire or an intrusion.
THIS CONTROL COMPLIES WITH NFPA REQUIREMENTS FOR
TEMPORAL PULSE SOUNDING OF FIRE NOTIFICATION APPLIANCES.
DINING
KITCHEN
BEDROOM
BEDROOM
BEDROOM
BEDROOM
LIVING ROOM
✪
✪
✪
✪
✪
▲
▲
BEDROOM
BDRM
BDRM
DINING
LIVING ROOM
TV ROOM
KITCHEN
■
■
■
✪
✪
✪
✪
✪
✪
▲
✪
✪
✪
BEDROOM
BEDROOM
TO
BR
■
■
■
■
■
LVNG RM
BASEMENT
KTCHN
▲
▲
.
CLOSED
DOOR
GARAGE
▲
Smoke Detectors for Minimum Protection
Smoke Detectors for Additional Protection
Heat-Activated Detectors
Recommendations for Proper Intrusion Protection
For proper intrusion coverage, sensors should be located at every possible point of entry to a home or
commercial premises. This would include any skylights that may be present, and the upper windows in a
multi-level building.
In addition, we recommend that radio backup be used in a security system so that alarm signals can still be
sent to the alarm monitoring station in the event that the telephone lines are out of order (alarm signals are
normally sent over the phone lines, if connected to an alarm monitoring station).
Содержание Vista-20Bay
Страница 2: ......
Страница 22: ...VISTA 20BAY Installation Setup Guide 3 4 ...
Страница 28: ...VISTA 20BAY Installation Setup Guide 4 6 ...
Страница 32: ...VISTA 20BAY Installation Setup Guide 5 4 ...
Страница 40: ...VISTA 20BAY Installation Setup Guide 6 8 ...
Страница 64: ...VISTA 20BAY Installation Setup Guide 14 4 ...
Страница 68: ...VISTA 20BAY Installation Setup Guide 15 4 ...
Страница 82: ...VISTA 20BAY Installation Setup Guide 16 14 ...
Страница 92: ...VISTA 20BAY Installation Setup Guide 17 10 ...
Страница 98: ...VISTA 20BAY Installation Setup Guide 18 6 ...
Страница 100: ...VISTA 20BAY Installation Setup Guide 19 2 ...
Страница 110: ...VISTA 20BAY Installation Setup Guide 22 4 ...
Страница 116: ...VISTA 20BAY Installation Setup Guide 23 6 ...
Страница 122: ...VISTA 20BAY Installation Setup Guide 25 4 NOTES ...
Страница 128: ...VISTA 20BAY Installation Setup Guide A 2 ...
Страница 130: ...VISTA 20BAY Installation Setup Guide B 2 ...
Страница 138: ... 1 9 l N7526 4V1 5 00 SINCE 1946 BAY ALARM 925 Ygnacio Valley Road Walnut Creek CA 94596 ...