29
USER Section
(en)
7221369.01 (1-03/15)
5. BOILER INFORMATION MENU
Press
to display the information indicated in the following table. Press
to exit.
Description
Description
00
SW Diagnostic Code
12
Ion current
01
Heating flow temperature
13
Burner working hours
02
Outdoor temperature (if the outdoor sensor is fitted)
14
Zone 1 heating mode
03
External storage tank temperature (fitted models)
15
Zone 2 heating mode
04
DHW temperature (fitted models)
16
DHW circuit operating mode
05
Water pressure in heating system
17
Boiler operating mode
06
Heating return temperature
18
Solar plant operating mode
07
Flue sensor temperature
19
Manufacturer information
08
Not used
20
Manufacturer information
09
Solar collector temperature
21
Gas energy consumption in HEATING
10
Zone 1 heating flow temperature
22
Gas energy consumption in DHW
11
Zone 2 heating flow temperature
23
Gas energy consumption in H DHW
Items 21, 22 and 23 are displayed alternatively with the gas energy consumption value expressed in millions, thousands and units
of kWh. e.g.: 21 / 033 / 145 / 827 corresponds to a gas energy consumption in HEATING of 33.145.827 kWh.
6. FILLING THE SYSTEM
Periodically check that the pressure displayed on the pressure gauge is
1
-
1.5
bar, with the system cold. If it is lower, turn the
system filling tap installed by the installer. Open the tap very slowly in order to vent the air.
The boiler is fitted with a hydraulic pressure gauge which prevents the boiler from working if there is no water.
If pressure drops occur frequently, have the boiler checked by the AUTHORISED TECHNICAL SERVICE CENTRE.
7. ROUTINE MAINTENANCE INSTRUCTIONS
To keep the boiler efficient and safe, have it checked by the Authorised Service Centre at the end of every operating period.
Careful servicing ensures economical operation of the system.
8. SWITCHING OFF THE BOILER
To turn off the boiler, disconnect the electric power supply using the two-pole switch. In the “Off” operating mode the boiler stays
off but the electrical circuits remain powered and the anti-freeze function remains active.
Содержание Luna Duo-Tec MP Plus 1.35
Страница 24: ...7221369 01 1 03 15 90 S E C T I O N A 20...
Страница 29: ...95 S E C T I O N C 7221369 01 1 03 15 G 3 4 G 1 G 1 95 123 100 100 CR_0774 75 5 51 5 43 22 O...
Страница 32: ...7221369 01 1 03 15 98 S E C T I O N F AGU 2 550 CR_0349 CR_0349 AVS 75...
Страница 33: ...99 S E C T I O N F 7221369 01 1 03 15 CG_2482 Tmax 50 C...