Country GB/IE Natural Gas
Appliance Category
CAT I
2H
Max Gas Rate
(m
3
/hr)
Both 2.68 Engine 0.82
Supplementary 1.86
Injector (mm)
Engine 4.1
Supplementary 5.6
Inlet Pressure
(Natural Gas G20)
mbar 20
Country GB/IE Propane Gas
Appliance Category
CAT I
3P
Max Gas Rate
(m
3
/hr)
Both 1.04 Engine 0.32
Supplementary 0.72
Injector (mm)
Engine 3.0
Supplementary 4.0
Inlet Pressure
(LPG G31)
mbar 37
Heat Input
(Net)
Max
Min
kW
25.3
3.7
Heat Input
(Gross)
Max
Min
kW
28.1
4.1
Heat Output
(NonCondensing)
Max
Min
kW
23.7
3.2
Heat Output
(Condensing)
Max
Min
kW
24.3
3.3
Appliance Type
C13
C33
C53
Electrical Supply
230V~ 50Hz
(Appliance must be connected to an earthed supply)
Power Consumption
24 model
150W
Electrical Protection
IPX4
External Fuse Rating
13A
Internal Fuse Rating for pump & diverter
valve
3.15A
Condensate Drain
To accept 21.5mm (3/4 in) plastic waste pipe
Flue Terminal Dimensions
Diameter
100mm
Projection
125mm
Connections
copper tails
Gas Supply
15mm
Central Heating Flow
22mm
Central Heating Return
22mm
Outercase Dimensions
Casing Height
950mm
Overall Height Inc Flue Elbow
1135mm
Casing Width
450mm
Casing Depth
426mm
NOx Class
5
Central Heating Primary Circuit Sealed System only
bar
Safety Discharge
3
Max Operating
2.5
Min Operating
0.5
Recommended
Operating
Range 12
Hydraulic Resistance
Frost Thermostat
5° C
Weights
Packaged Boiler Carton 117kg
Installation Lift Weight
110kg
Clearances
Above Casing
300 mm Min (horizontal flue)
200 mm Min (vertical flue)
Below Casing
200 mm Min
Front
450 mm Min (For Servicing)
Front
5 mm Min (In Operation)
L.H. Side
5 mm Min
R.H. Side
60 mm Min (In Operation)
Содержание ECOGEN 24/1.0
Страница 69: ...Fig 77 Fig 78 Fig 79 page 69 16 0 Schematic Wiring 16 1 Burner Control Units BCU Connections...
Страница 70: ...page 70 16 2 Milligrid 24 way Connector...
Страница 71: ...page 71 16 3 14 way Connector...
Страница 72: ...page 72 16 4 Engine Circuit...
Страница 73: ...page 73 16 5 Power Monitoring 24Vdc Power Supply...
Страница 74: ...page 74 16 6 External Connections External Wiring...
Страница 85: ...page 87...
Страница 86: ...page 88...
Страница 87: ...page 89 Section P...
Страница 88: ...page 90...
Страница 89: ...page 91 Section Q Engine developing less than 950W after 15 minutes running at maximum rate...
Страница 91: ...page 93 page 94 page 95 page 96 MICRO CHP SYSTEM COMMISSIONING CHECKLIST...
Страница 92: ...page 97...