15.2 Air/Gas Valve Setup Procedure
The preferred method is to use a micro manometer as outlined below, however if a micro manometer is not available a combustion analyser may be used as described below.
Using a Micro Manometer to adjust the valve offset.
Procedure to correctly set new Air/Gas Valve using a micro manometer. Connect the micro manometer with the appliance off fan not running as below.
1. Loosen screw in the internal pressure test point (PINT) and connect to + (positive) side of differential micro manometer.
2. Tee the (negative) side of the micro manometer into the air sense tube (
).
3. Ensure micro manometer is in Pa or mbar scale and has zeroed correctly. If in doubt, rezero the instrument.
4. Use the chimney sweep function to enable either Engine or Supplementary minimum rate. Before the air/gas valve opens, the pressure shown should be negative ie. 30Pa
or 25Pa respectively for each burner.
5. When the burner lights see that the reading is 5 to 6Pa if outside these values use the offset screw to adjust the 4mm hexhead underneath the dust cover.
NOTE: Turning adjustment screw clockwise reduces negative differential; anticlockwise increases negative differential.
A 4mm hexagon key should be used to make the adjustment.
6. Now check the combustion Carbon dioxide and Carbon Monoxide at the maximum rate for each air/gas valve.
Using a Combustion Analyser to adjust the valve offset.
Follow the procedure as outlined in
. paragraph 16 to adjust the Carbon Dioxide percentage at the maximum rate.
For the supplementary the CO2 should be 9.0% ± 0.3
For the engine the CO2 should be 9.0% ± 0.3
Propane Gas When either burner is tested individually at maximum rate: The CO2 should be 10.2% ± 0.3.
1a. To adjust the offset check the Carbon Dioxide percentage at the minimum rate. Remove the offset adjustment dust cover using a flat bladed screw driver and adjust the offset
using a 4 mm hex driver to give the following percentages:
Supplementary the CO2 should be 8.7% ± 0.3 (minimum rate)
Engine the CO2 should be 8.8% ± 0.3 (minimum rate)
Propane Gas CO2 at minimum rate:
The CO2 should be 9.6% ± 0.3 for the supplementary
The CO2 should be 9.8% ± 0.3 for the engine
2a. Recheck the Carbon Dioxide % at max rate, adjust the throttle adjustment screw if necessary.
3a. The differences between the maximum/minimum percentages should be as close as possible to the differences in the ranges quoted; they must not be equal or less.
i.e.: For the Supplementary burner maximum rate, the Carbon Dioxide should be around 0.6 % greater than at the minimum rate.
For the Engine burner maximum rate, the Carbon Dioxide should be around 0.2% greater than at the minimum rate.
Содержание ECOGEN 24/1.0
Страница 69: ...Fig 77 Fig 78 Fig 79 page 69 16 0 Schematic Wiring 16 1 Burner Control Units BCU Connections...
Страница 70: ...page 70 16 2 Milligrid 24 way Connector...
Страница 71: ...page 71 16 3 14 way Connector...
Страница 72: ...page 72 16 4 Engine Circuit...
Страница 73: ...page 73 16 5 Power Monitoring 24Vdc Power Supply...
Страница 74: ...page 74 16 6 External Connections External Wiring...
Страница 85: ...page 87...
Страница 86: ...page 88...
Страница 87: ...page 89 Section P...
Страница 88: ...page 90...
Страница 89: ...page 91 Section Q Engine developing less than 950W after 15 minutes running at maximum rate...
Страница 91: ...page 93 page 94 page 95 page 96 MICRO CHP SYSTEM COMMISSIONING CHECKLIST...
Страница 92: ...page 97...