![Baxi EcoBlue Advance 16 Heat ErP Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/baxi/ecoblue-advance-16-heat-erp/ecoblue-advance-16-heat-erp_installation-and-service-manual_2711776045.webp)
Fig. 49 & Fig. 50
page 53
10.3.6 Flow Temperature Sensor (
Fig. 51
)
The sensor is fitted in a 'dry' pocket.
Disconnect the wiring from the flow temperature sensor.
1.
Unscrew the sensor from the top of the heat exchanger.
2.
Fit the new sensor and reconnect the wiring.
3.
10.3.7 Overheat Sensor (
Fig. 51
)
The sensor is fitted in a 'dry' pocket.
For ease of access remove the Flow Temperature Sensor (
10.3.6
)
Disconnect the wiring from the overheat sensor.
1.
Unscrew the sensor from the top of the heat exchanger.
2.
Fit the new sensor and reconnect the wiring.
3.
Baxi EcoBlue Advance 13, 16, 19, 25, 30 Heat ErP Installation Manual