9.4
Reading out measured values
9 Settings
Fig.6
5
Heating curve graph
58
C
5
CPP21
1
5
CP2 21
1
0
0
0
/
/
C
C P220
=
=
= 2
30
CP210
/ C P2
P22 20
0
40
CP210
/
/
C
C
P2
P2
2
2
0
0
=
= 50
CP200 = 20
CP230 = 1.5
PreheatSetpoint = 0
CP000
SP_CH (°C
)
Tout (°C)
CP000
Tout (°C)
CP200 = 20
CP210 = 15
PreheatSetpoint = 0
SP_CH (°C
)
CP23
0 = 4
CP230 = 3
CP230 = 2
CP230 = 1.5
CP230 = 1.0
Tout (°C)
CP000
CP230 = 1.5
CP210 = 15
PreheatSetpoint = 0
CP200 = 30
CP200 = 25
CP200 = 20
CP200 = 16
SP_CH (°C
)
BO-0000232
Tout: temperature detected by the outside sensor (° C)
SP_CH: Heating flow temperature setpoint (°C)
Proceed as described below to access the info menu:
Press the F3 key;
The
symbol flashes on the display;
Press the F4 key to access the INFO menu;
Turn the
knob to view the settings;
Press the F1 key to exit.
Setting
(read only)
Description
Value
AM001
DHW (Domestic Hot Water) mode enabled (0: Disabled, 1: Enabled)
0/1
AM010
Pump speed (0 ÷ 100%)
%
AM011
Service required (0: Disabled, 1: Enabled)
0/1
AM012
Status of appliance
List of statuses
AM014
Sub Status of appliance
List of sub-sta
tuses
AM015
Pump operation (0: Disabled, 1: Enabled)
0/1
Fig.6
6
INFO menu access
BO-0000230-14
Tab.
28
Read-only parameter list (not editable)
F1
F1
F1 F2
F4
Combi 2
Note
Explain to the user how to select a different temperature curve and
how the outdoor sensor regulates the boiler flow temperature.
Important
When an OpenTherm controller is connected adjustment of the
boiler, e.g. heating temperature, is made using the OpenTherm
controller rather than the boiler controls. The boiler controls are
overridden by the OpenTherm control. Please check the function
ality with the manufacturer of the OpenTherm controller.