9 Settings
5
5
Name
Description
Factory
value
Minimum
Maximum Level
DP003
Maximum fan speed in domestic hot water mode
[rpm]
See chapter
"Service Set
tings"
–
–
Installer
DP004
Anti-legionella function
0: Disabled
1: Weekly
2: Daily (only available with Room Unit)
0
–
–
User
DP005
Difference between the flow temperature and the
temperature requested by the calorifier tank [°C]
15
0
25
Installer
DP006
Difference between the temperature detected by the
calorifier tank sensor and the desired DHW tempera
ture that enables a heat request [°C]
4
2
15
Installer
DP007
Position of three-way valve in standby
0: CH operation
1: DHW (Domestic Hot Water)
1
–
–
Installer
DP034
Corrects in a negative sense the value measured by
the calorifier tank sensor [°C]
0
0
10
Installer
DP070
Domestic hot water temperature setpoint.
In the case of operation with a calorifier tank and pro
gramming via room unit corresponding to the comfort
setpoint [°C]
* Depends on the marke
(55/60) *
35
(60/65) *
User
DP150
Enabling the calorifier tank sensor/thermostat
0: DHW (Domestic Hot Water) sensor
1: DHW (Domestic Hot Water) thermostat
1
–
–
Installer
DP160
Temperature setpoint of the anti-legionella function
[°C]
65
60
90
Installer
DP200
DHW mode:
0: Domestic hot water programming (only available
with Room Unit)
1: Manual (boiler with calorifier tank) – Preheating ac
tive (instantaneous boiler)
2: Antifreeze (boiler with calorifier tank) – No preheat
ing (instantaneous boiler)
2
–
–
User
DP410
Duration of the DHW anti-legionella program [mi
nutes]
3
0
600
Installer
DP420
Maximum anti-legionella duration time [minutes]
15
0
360
Installer
DP430
Day to start the DHW anti-legionella program [day]
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
1
1
7
Installer
DP440
Starting time for the DHW anti-legionella program
[minutes]
30
0
143
Installer
GP007
Maximum fan speed in heating mode [rpm]
See chapter
"Service Set
tings"
–
–
Installer
GP008
Minimum fan speed [rpm]
See chapter
"Service Set
tings"
–
–
Installer
GP009
Fan starting speed [rpm]
4300
2500
6000
Installer
GP082
Enabling domestic water circuit during chimney
sweep function
0
0
1
Installer
PP015
Pump post circulation run time after heating mode re
quest [min]
3
0
99
Installer
PP016
Maximum pump speed in heating mode [%]
100
8
0
100
Installer
Combi 2