9 Settings
Tab.
29
List of statuses
STATUS
Standby
0
Heat request
1
Burner ignition
2
Operation in heating mode
3
Operation in domestic water mode
4
Burner off
5
Pump post circulation
6
Burner shutdown to reach the temperature setpoint
8
Temporary fault
9
Permanent fault (fault to be reset manually)
10
Chimney sweep function at minimum output
11
Chimney sweep function at maximum output in heating mode
12
Chimney sweep function at maximum output in domestic water mode
13
Manual heat request
15
Frost protection function active
16
Venting function active
17
Boiler reset in progress
19
Tab.3
0
List of sub-statuses
SUB-STATUS
Standby
0
Wait time until next ignition in heating mode
1
Pre-ventilation
13
Burner ignition signal sent to safety core
15
Burner pre-ignition
17
Burner ignition
18
Flame check
19
Fan operation during ignition attempts
20
Operation at set temperature setpoint
30
Operation at limited temperature setpoint
31
Operation at required output
32
Level 1 gradient detected
33
Level 2 gradient detected
34
Level 3 gradient detected
35
Flame protection active
36
Stabilisation time
37
Boiler start at minimum output
38
Operation in heating mode has been interrupted by a domestic hot water request. Restart from power output in which
it was interrupted.
39
Post ventilation
41
Fan off
44
Output reduction due to high flue gas temperature
45
Pump post circulation
60