![Baxi Bermuda SP3 Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/baxi/bermuda-sp3/bermuda-sp3_installation-and-servicing-manual_2711686033.webp)
Supplied By www.heating spares.co Tel. 0161 620 6677
Control Tap and Micro-Switch
1
Remove the control knob by pulling from the spindle.
Remove the two screws holding the bezel in place.
Disconnect the two electrical connections from the
light switch, taking note of their orientation. Remove
the bezel.
2
Release the thermocouple from the control tap
by unscrewing the retaining nut.
Disconnect the two
electrical connections
from the micro switch.
Release the nut-and-olive
connections on the control tap
body and disconnect the gas
pipes from the control tap.
Disconnect the gas inlet at the
control tap by releasing the
compression fitting.
3
Release the locknut fixing
the control tap to the
chassis. Access to the
locknut may be gained
through the bezel location.
Withdraw the control tap
from the fire.
4
At this point change the micro-switch if required by
removing the circlip holding it in position on the control
tap.
Fit the new micro-switch or the new control tap in
reverse order.
Make good all gas and electrical connections.
Temporarily reconnect electricity supply. Light the
fire, turn off the electricity supply and check all
joints for gas soundness. Turn the fire off. Re-
assemble all components in reverse order to
dismantling.
33
1
2
3
4