Glass Frame
1
Ensure that the glass panel is cold. Disengage the
retaining clamps.
Lift the frame away.
Fix the new glass frame in position and engage the
retaining clamps. Re-assemble the components in the
reverse order to dismantling.
Frame Sealing Rope
1
Ensure that the glass panel is cold. Disengage the
retaining clamps.
Lift the frame away.
2
Pull the old rope seal out of the locating channel and
release the glass locating brackets.
Fit the new seal, starting at the centre, tuck
well into the locating channel. Ensure
that there is an equal amount of seal
free at either end of the channel.
Secure the glass locating brackets.
Fix the glass frame in position and
engage the retaining clamps. Re-
assemble the components in the
reverse order to dismantling.
Check that the seal between the
rope and the glass frame is good.
Coal Bed
1
Ensure that the glass panel is
cold. Disengage the retaining clamps.
Lift the frame away.
3
Lift the coal bed away from the locating pins.
Carefully fit the new coal bed in position on the
locating pins. Fix the glass frame in position and
engage the retaining clamps. Re-assemble the
components in the reverse order to dismantling.
CAUTION: The coal bed is extremely fragile and
must be handled accordingly. Gloves should be
worn and any inhalation of the dust should be
avoided. Keep the coals away from children at all
times. Please read the Important Information
section on page 5.
Bermuda SP3
showing hearth
in position
1
2
3
Bermuda VP3
showing hearth
in position
28