Electrode Lead

1

Remove the insulating sleeve from the body of the
electrode. Disconnect the electrode lead from the
electrode.

2

Disconnect the electrode lead from the spark
generator.

Undo the screw holding the orange panel to the
chassis. Lift the panel upwards and withdraw the
sleeve and lead.

Thread the new electrode lead through the

insulating sleeves. Fit the new electrode

lead to the spark generator and

electrode.

Re-assemble the components in

the reverse order to dismantling.

Spark Generator

Remove the front screw holding the

spark generator in place, and release

the rear screw, enabling the

generator to be removed.
Disconnect the electrical
connections and electrode lead.

Fit the new spark generator and re-

assemble all components in the

reverse order to dismantling.

Resistor

Remove the two screws securing the light shield

bracket. Unclip the resistor from the side frame.
Disconnect the two resistor wires from the terminal
strip. Replace resistor and refit in reverse order.

2

1

31

Содержание Bermuda SP3

Страница 1: ...Supplied By www heating spares co Tel 0161 620 6677 Please leave these Instructions with the User Baxi Bermuda SP3 VP3 Fireside Gas Central Heating Unit SP3 VP3 Installation and Servicing Instructions ...

Страница 2: ...s know Natural Gas Baxi Bermuda SP3 G C No 37 077 63 Baxi Bermuda VP3 G C No 37 077 62 For use with the following boilers Baxi Bermuda 45 4 M G C No 44 077 71 Baxi Bermuda 45 4 E G C No 44 077 73 Baxi Bermuda 57 4 M G C No 44 077 72 Baxi Bermuda 57 4 E G C No 44 077 74 Baxi Bermuda 51 5 G C No 44 075 06 Baxi is a BS EN ISO 9001 Accredited Company Renewal Baxi Bermuda SP3 Renewal G C No 37 075 05A ...

Страница 3: ...ealing Rope Coal Bed Burners and Injectors Light Switch Electrode Lead Spark Generator Resistor Pilot ASD Assembly Electro Magnetic Unit Control Tap and Micro switch PAGE 34 35 PAGE 36 PAGE 37 Supplementary Instructions Burner Removal Burner Replacement PAGE 38 39 Supplementary Kit Instructions Existing Fire Boiler Adaptation Introduction Technical Data Site Requirements Installation Commissioning...

Страница 4: ...t I E E Wiring Regulations Where no specific instructions are given reference should be made to the relevant British Standard Code of Practice In IE the installation must be carried out by a competent Person and installed in accordance with the current edition of I S 813 Domestic Gas Installations the current Building Regulations and reference should be made to the current ETCI rules for electrica...

Страница 5: ...e output settings Position OFF Position IGNITION PILOT Position 1 LOW Position 2 MEDIUM Position 3 MEDIUM HIGH Position 4 HIGH The artificial coal bed may be illuminated by concealed bulbs as and when required The light effect is operated by a switch situated below the control knob It may be used whether the fires are ON or OFF Important Information This product contains Refractory Ceramic Fibres ...

Страница 6: ...2 000 Heat Input Gross High Med High kW 5 74 4 95 Btu h 19 600 16 900 Heat Input Gross Med Low kW 3 43 2 07 Btu h 11 700 7 100 Setting Pressure Cold mbar 12 8 0 5 in wg 5 12 0 2 Gas Connection The gas supply is provided from the service cock on the boiler unit Electricity Supply230V 50Hz 3A 120W External fuse 3A Controls Rotary gas tap with Atmospheric sensing device Electronic ignition Lifting We...

Страница 7: ... sited in another room provided an interconnecting vent is used The vent must not be installed inside the builders opening The vent should be sited following good practice for a habitable room We recommend the use of the Stadium BM720 Black Hole ventilator which is available from your local merchant HEARTH MOUNTING If the fire unit is to be hearth mounted then the hearth must be of a non combustib...

Страница 8: ...tate complete electrical isolation of the appliance Connection may be made via a fused double pole isolator with a contact separation of at least 3mm 1 8 in in all poles and serving the appliance and systems control only max fuse rating 3 amp A permanent electricity supply to the boiler is required WARNING THIS APPLIANCE MUST BE EARTHED 4 core input cable for connection to the boiler unit must NOT...

Страница 9: ...he boiler controls assembly as described in the boiler Installation and Servicing Instructions The socket should be wired as described in the boiler Installation and Servicing Instructions Remove the screw fixing the input socket to the boiler base Slide the socket to the right then lift to remove Remove the screw fixing the cover to the socket housing and remove the plastic cover revealing the te...

Страница 10: ...ked L2 Route the green yellow wire earth through the cut out in the socket housing and connect it to the earth terminal The earth wire should be long enough so that the live and neutral wires will become taut before the earth wire if the cable is pulled Refit the socket cover and fix in place with the screw Refit the input socket assembly to the boiler base and fix in place with the securing screw...

Страница 11: ...onic ignition the plug must be wired as shown Connect the control switched live to L Connect neutral to N Connect earth to The live of the fire supply cable must also be connected to the terminal block Neutral and Earth of the fire supply cable can then be connected to N and respectively If the firefront does not require a permanent live feed wire the plug as shown The loose terminal block can be ...

Страница 12: ...with either lighting effects or lighting effects and electronic ignition the plug must be wired as shown Connect the control switched live to SL Connect neutral to N Connect earth to Connect the permanent live to L The fire earth must connect to the chassis Neutral and Live of the fire supply cable can then be connected to N and L respectively If the firefront does not require a permanent live fee...

Страница 13: ...t length Measure the distance from the centre of the front V mark on the boiler base tray to the face of the wall or surround Let this distance be known as distance D Mark off distance D from the plain end of the supply tube cut and dispose of the unwanted piece of tube Care must be taken to ensure that the cut is square and that the pipe is free from burrs and swarf An alternative method of deter...

Страница 14: ...p corner fixing hole positions otherwise space the fixing holes as far apart as possible Remove the fire unit from the hearth and remove the backing plate from the fire chassis by removing the two screws holding it in position Retain the screws Drill the fixing holes in the surround wall face to accept suitable wall plugs Fix the backing plate in position on the wall using suitable screws NOTE For...

Страница 15: ... by adjusting the front feet check using a spirit level Mark the positions of the available fixing holes in the backing plate NOTE Where possible use the top corner fixing hole positions otherwise space the fixing holes as far apart as possible Remove the fire unit from the support plate and remove the backing plate from the fire chassis by removing the two screws holding it in position Retain the...

Страница 16: ... on the burner CAUTION The coal bed is extremely fragile and must be handled accordingly Gloves must be worn and any inhalation of the dust should be avoided Keep the coals away from children at all times Please read the Important Information section on page 4 Remove any labels fixed to the glass frame assembly and clean both sides of the glass panels using a non abrasive cream cleanser before rep...

Страница 17: ...lectrical cover on the right hand side of the chassis by removing the fixing screw Release the pressure test point sealing screw and connect a pressure gauge in position Push in the control knob turn to the IGNITION position and hold in Sparking will commence at the ignition electrode and the pilot will ignite Continue to hold the control knob in for a further 15 seconds then release The sparking ...

Страница 18: ...closed If there is an extractor fan or ceiling fan in the room or any adjoining room the check for spillage must be performed with the fan turned on and any interconnecting doors open Ignite the fire and turn to setting 4 After running for 5 minutes take a lighted smoke match and insert it into the boiler down draught diverter as shown WARNING CARE MUST BE TAKEN TO AVOID TOUCHING HOT PANELS AT THI...

Страница 19: ... 8 x 5 8in screws in the front and the two M4 x 8mm thread former screws in the sides Hang the left and right hand side doors on the fittings as shown and close the doors ensuring that they lock in position Fix the canopy by lowering it into position over the top edge and then by gently easing the sides inwards push home to lock in place Locate the fender front in position at the front of the hear...

Страница 20: ... using the two 3 8 in screws in the sides Hang the left and right hand side doors on the fittings as shown leaving them open Fix the canopy by guiding the bottom edge onto the door pins and then by tilting the back edge over the locating lip on the innercase Close the doors ensuring they lock in place Instruct the user in the operation of the fire controls and hand over the user s instructions and...

Страница 21: ...mely fragile and must be handled accordingly Gloves should be worn and any inhalation of the dust should be avoided Keep the coals away from children at all times ISOLATE THE GAS AND ELECTRICITY SUPPLY TO THE BOILER AND FIRE UNITS INCLUDING THE PERMANENT LIVE Remove the canopy by gently easing the sides inwards and pulling the bottom edge forward then lift the canopy upwards and away from the loca...

Страница 22: ...late CAUTION The coal bed is extremely fragile and must be handled accordingly Gloves should be worn and any inhalation of the dust should be avoided Keep the coals away from children at all times ISOLATE THE GAS AND ELECTRICITY SUPPLY TO THE BOILER AND FIRE UNITS INCLUDING THE PERMANENT LIVE Remove the canopy firstly by opening the left and right hand side doors then lift the canopy by the bottom...

Страница 23: ...ed separately from the boiler Disconnect the 3 pin plug from the socket beneath the fire Turn off the gas service cock by turning fully clockwise Disconnect the fire supply pipe from the fire inlet Remove and retain the two screws fixing the chassis to the backing plate Pull the fire forwards until the flue spigot is clear of the boiler canopy and lift away Manual Controls Boiler shown 23 ...

Страница 24: ... A S D pilot assembly must not be adjusted in any way The A S D must not be altered so that it will not operate or be bypassed in any way Ensure that the pilot burner aeration hole is free from lint debris etc If necessary clean the electrode and target and check that the spark gap is 2 5 4 0mm The thermocouple cannot be changed as an individual component The complete assembly must be replaced in ...

Страница 25: ...LL COMPONENTS Examine the glass frame if the glass is in any way damaged then it must be replaced NOTE This is a heat resistant glass and must not be replaced by ordinary glass The glass may be cleaned with a non abrasive cream cleansing agent if required Examine the glass frame sealing rope on the fire and replace it if in any way damaged Examine the coal bed and replace it if any major damage ha...

Страница 26: ...change the ELECTRODE LEAD SPARK GENERATOR and RESISTOR remove the canopy side doors fender front and hearth assembly as shown To change the PILOT A S D ASSEMBLY ELECTRO MAGNETIC UNIT CONTROL TAP and MICRO SWITCH remove the canopy side door fender front and hearth assembly The fire must then be disconnected from the gas supply and removed from the fireplace to give access to the rear of the unit as...

Страница 27: ...ons for this appliance To change the ELECTRODE LEAD SPARK GENERATOR and RESISTOR remove the canopy side doors and hearth as shown To change the PILOT A S D ASSEMBLY ELECTRO MAGNETIC UNIT CONTROL TAP and MICRO SWITCH remove the canopy side door and hearth The fire must then be disconnected from the gas supply and removed from the fireplace to give access to the rear of the unit as follows 1 Disconn...

Страница 28: ...ackets Fix the glass frame in position and engage the retaining clamps Re assemble the components in the reverse order to dismantling Check that the seal between the rope and the glass frame is good Coal Bed 1 Ensure that the glass panel is cold Disengage the retaining clamps Lift the frame away 3 Lift the coal bed away from the locating pins Carefully fit the new coal bed in position on the locat...

Страница 29: ...curing the burner to its support brackets 4 Disconnect the compression nuts from the injectors and carefully remove the burner to avoid damaging the pilot assembly 5 Remove the injectors from the old burner and fit them into the new burner or if required fit new injectors flat end in the burner taking care not to over tighten them in their mountings Re assemble the components in the reverse order ...

Страница 30: ... of the two electrical connections and disconnect from the switch Remove the bezel 4 Press together the retaining arms on the rear of the switch and remove from the bezel Fit the new switch in place ensure that the orientation of the switch is correct i e with the O symbol towards the front of the fire and make good the electrical connections Re assemble the components in the reverse order to dism...

Страница 31: ...electrode lead to the spark generator and electrode Re assemble the components in the reverse order to dismantling Spark Generator Remove the front screw holding the spark generator in place and release the rear screw enabling the generator to be removed Disconnect the electrical connections and electrode lead Fit the new spark generator and re assemble all components in the reverse order to disma...

Страница 32: ...he gas tap 3 Remove the screws holding the pilot assembly bracket to the fire chassis Unclip the thermocouple from the fire chassis Withdraw the pilot assembly and bracket Remove the screw holding the assembly to the bracket Re assemble all components in the reverse order to dismantling Electro Magnetic Unit 4 Release the thermocouple from the control tap by unscrewing the retaining nut 5 Release ...

Страница 33: ...the gas pipes from the control tap Disconnect the gas inlet at the control tap by releasing the compression fitting 3 Release the locknut fixing the control tap to the chassis Access to the locknut may be gained through the bezel location Withdraw the control tap from the fire 4 At this point change the micro switch if required by removing the circlip holding it in position on the control tap Fit ...

Страница 34: ... across microswitch Consult Gas Supplier Turn on gas supply Is gas supply turned on Is supply pressure correct 20mb working NO YES NO YES YES NO Has new pilot filter been fitted YES NO Adjust spark gap NO YES Is pilot burner clean Change pilot assembly NO YES Is spark gap 2 5 to 4mm The thermocouple cannot be changed as an individual component The complete assembly must be replaced in the event of...

Страница 35: ... YES NO YES Are gas cocks fully open Replace both bulbs Does one bulb light Do both bulbs light Are plug socket under spark generator connected 230v across micro switch when operated 230v across resistor Are bulbs switched on NO NO YES YES YES YES Are pilot flames stable and approx 20mm long YES Isolate mains Rectify flue YES NO Connect plug and socket Replace switch Make good the connection Is th...

Страница 36: ...094 Burner 225400 79 81 156 432 Coal Bed 236103 81 83 397 681 Injector Burner FO2 226910 82 84 378 988 Spark Generator 233254 87 91 387 916 Electrode Lead 2 8mm 236184 83 85 386 129 Resistor 68 228955 72 74 205 723 Pilot Filter 082412 The following components are unique to the VP3 PROPANE appliance only Key No s G C Description Manufacturers No Part No 70 E00 855 Gas Tap LPG 237082 80 E00 857 Burn...

Страница 37: ...d only with the Bermuda 553 Propane The Heat Input Heat Output and Setting Pressures given in the Instructions Booklet do not apply to the Propane appliance Refer to the table opposite Burner Removal See page 29 and read instruction 4 in conjunction with the paragraph below The left hand locating pin does not secure the burner to the support bracket To remove the burner unscrew the right hand loca...

Страница 38: ...ned appliance Remove the controls cover panel from the front of the fire Remove the tap control knob Disconnect the electrical socket from the fire plug if fitted Remove the screws securing the outercase to the innercase Lift off the outercase Turn the gas service tap to the Boiler only position by turning 1 4 turn clockwise Remove the radiants if fitted Disconnect the supply pipe at the fire inle...

Страница 39: ...ews provided Use the centre group of holes at each side NOTE If the fire is being used with a Bermuda 401 boiler unit the support brackets from the previous plate must be fitted before the fire support plate can be fixed in place Push the support plate backwards until it touches the surround or wall face and tighten the screws to lock it in position BERMUDA 45 3 57 3 45 4 57 4 51 5 Take the fire s...

Страница 40: ...ing spares co Tel 0161 620 6677 Comp No 237568 Iss 9 1 03 B A X I P O T T E R T O N Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN After Sales Service 08706 096 096 Technical Enquiries 08706 049 049 www baxi co uk ...