14.8 Fitting the Fusion firefront.
1.
The Fusion firefront is secured in place using four
screws. Locate the firefront brackets with the holes in
the bottom of the firebox and secure each both sides
with the two ‘B’ screws supplied (See figure 61).
2.
Hang the lower firefront / ‘Ash pan’ on the firefront.
15. SPILLAGE AND FLAME SUPERVISION CHECKS
15.1 Check for spillage.
1.
Close all doors and windows in the room containing the appliance.
2.
Light the appliance and turn the control knob to “HIGH”.
3.
Leave the appliance on for five minutes.
4.
Place the smoke match into the appliance canopy (See figure 62).
5.
The installation is satisfactory if the smoke is drawn into the appliance. If the smoke
is not drawn into the appliance, leave the appliance alight at the maximum setting for a
further ten minutes and then repeat the test. If smoke is still not drawn into the
appliance, inspect the sealing to the fireplace surround. If the sealing is satisfactory but
Page 36
INSTALLER GUIDE
A spillage check must be made before leaving the installed appliance with the
customer. Make this with all the ceramic fuel effect pieces and firefront casting /
firefront in position
.
Figure 60. ‘ash pan’ location
Figure 61.Fusion firefront