12.9 Fitting the Bolero firefront.
1.
Place the fascia against the fireplace
front surface so that the two retaining
plates at the back of the fascia are directly
above the two upper retaining brackets at
the top of the convection box. Lower the
fascia making sure that the retaining plates
locate fully over the brackets on the
convection box (See figure 34).
2.
Fix the bottom of the fascia unit to the
convection box with two screws (See figure
35).
13. SPILLAGE AND FLAME SUPERVISION CHECKS
13.1 Check for spillage.
1.
Close all doors and windows in the room containing the appliance.
2.
Light the appliance and turn the control knob to “HIGH”.
3.
Leave the appliance on for five minutes.
4.
Place the smoke match into the appliance canopy (See figure 36).
5.
The installation is satisfactory if the smoke is drawn into the appliance. If the smoke
is not drawn into the appliance, leave the appliance alight at the maximum setting for a
further ten minutes and then repeat the test. If smoke is still not drawn into the
Page 32
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
A spillage check must be made before leaving the installed appliance with the
customer. Make this with all the ceramic fuel effect pieces and firefront casting /
firefront in position
.
Figure 35. Bolero Fascia bottom
location.
Figure 34. Bolero Fascia location