10.3 Inlet pressure check.
The appliance is pre-set to give the correct heat input
at the inlet pressure shown in section 2 of this
manual. No adjustment is necessary.
1.
Check the inlet pressure by fitting a pressure
gauge at the test point. The test point is on the inlet
elbow (See figure 21). Check the pressure with the
appliance alight and set at maximum output.
2.
After checking, turn off the appliance. Remove the
pressure gauge and replace the test point sealing
screw.
3.
Relight the appliance. Turn to the maximum
output position and test around the sealing screw for gas soundness with a suitable leak
detection fluid.
When the above checks from section 10.2 and 10.3 have been completed close the
isolating valve on the inlet elbow
.
11. CERAMIC WALLS INSTALLATION
1.
Fit the ceramic rear wall inside the “L”
bracket on the back face of the burner
compartment. Push the ceramic wall flat
against the back face of the burner
compartment (See figure 22).
2.
Fit the ceramic side walls against the side
faces of the burner compartment. The bottom
edges of the walls should rest in the ledges at
the sides of the firebox. Slide them in from
the front and ensure that
they touch the rear wall. Be
careful not to damage the
edges of the side walls (See
figure 23).
Page 28
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 23. Ceramic side walls installation
Figure 22. Ceramic rear wall installation
Figure 21. Pressure test point