en_BA_OXH7_PosCon_TCP_IP.docx
60/98
Baumer Electric AG
Friday, June 15, 2018 12:44:11 PM/tof V1.0 ANW_81184815
Frauenfeld, Switzerland
Address
Parameter description
Data type
220
Set Field of View:
The command does not care which number is written.
uint16_t
Address 250 – Flex Mount Reset
Writing any value to this register resets the Flex Mount parameters to their defaults.
Function
Holding register (FUNCTION 03/06/16)
Address
250
Length
1
Access
Write Only
Address
Parameter description
Data type
0
Reset Flex Mount:
The command does not care which number is written.
uint16_t
Address 251 – Flex Mount
Function
Holding register (FUNCTION 03/06/16)
Address
251
Length
4
Address
Parameter description
Data type
251-252
Angle [deg]
float32_t
253-254
Distance [mm]
float32_t
Address 255 – Teach Flex Mount
Writing to this register teaches the currently measured surface as a Flex Mount reference surface.
Function
Holding register (FUNCTION 03/06/16)
Address
255
Length
2
Access
Write Only
Address
Parameter description
Data type
255-256
Reference correction [mm]
float32_t
4.2.3.1
4.2.3.1