3.3.2.2.3 Field of view limits
All measurement values outside the set field of view are ignored. This is particularly useful if, for example, the
field of view contains an unwanted object that is not to be detected.
The field of view is adapted by software so the width of the visible laser beam does not change.
For full flexibility, every value in the field of view can be individually adjusted. The modified field of view need
not be symmetrical. Even a single limit, e.g., Left Limit, can be restricted.
Right Limit
( mm)
Left Limit
( mm)
Left
Right
Right Limit
( mm)
Left Limit
( mm)
Left
Right
90° installation
Angled installation (Flex Mount)
NOTE
If a reference surface is teached with Flex Mount, the reference point of that teached level
represents 0. Left Limit and Right Limit are specified from there.
Reference surface
(teached)
Reference line
(Middle of field
Reference line
(Middle of field
of view)
Reference
point
Reference
point
Field of view
limited
Field of view
limited
NOTE
The minimum width of the field of view (Left Limit to Right Limit) must be
at least 2 mm.