Active parameters
Data Acquisition
3.3.2.1.1 .3.2.1.1isi t
To improve sensitivity to dark objects, the exposure time can be increased. This also changes the measuring
repeat time.
Light object: Short exposure time for light, shiny, and reflective surfaces such as metal or white objects, for
example.
Dark object: Longer exposure time and therefore slower measuring frequencies for plastics or black materials,
for example.
3.3.2.1.2 Trigger mode
For setting the measuring intervals.
Free running
Measurement with the max. possible frequency, which may vary depending on the application. The sensor
measures continuously.
Interval
Measurement cycle with fixed internal interval (time in ms). The constant measuring frequencies that can be
achieved are slower than the non-constant frequencies in free-running mode. The interval must be set
accordingly.
NOTE
- If Sync-In (pin 8) is connected, free-running mode (or interval mode) runs when Sync-In is set to low
- If Sync-In is not connected, free-running mode (or interval mode) runs continuously
NOTE
Sometimes, shiny surfaces may require a longer exposure time.