![Baumer PosCon OXH7 Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/baumer/poscon-oxh7/poscon-oxh7_manual_2710829059.webp)
en_BA_OXH7_PosCon_TCP_IP.docx
59/98
Baumer Electric AG
Friday, June 15, 2018 12:44:11 PM/tof V1.0 ANW_81184815
Frauenfeld, Switzerland
Address
Parameter description
Data type
100
Exposure Time Mode
0 = Short
1 = Long
uint16_t
Address 101 – Precision
Function
Holding register (FUNCTION 03/06/16)
Address
101
Length
1
Address
Parameter description
Data type
101
Precision Mode
0 = Normal
1 = High
2 = Very High
uint16_t
Address 200 – Field of View
Function
Holding register (FUNCTION 03/06/16)
Address
200
Length
8
Address
Parameter description
Data type
200-201
Left Limit [mm]
float32_t
202-203
Right Limit [mm]
float32_t
204-205
Offset [mm]
float32_t
206-207
Height [mm]
float32_t
Address 220 – Field of View to MAX
Writing any value to this register sets the field of view to its maximum possible size.
Function
Holding register (FUNCTION 03/06/16)
Address
220
Length
1
Access
Write Only
4.2.3.1
4.2.3.1
4.2.3.1