en_BA_OXH7_PosCon_TCP_IP.docx
54/98
Baumer Electric AG
Friday, June 15, 2018 12:44:11 PM/tof V1.0 ANW_81184815
Frauenfeld, Switzerland
4.2.3
Modbus TCP commands: Holding register
Overview of index commands for holding register function 03/6/16
Address
Length
Command
0
1 Enter Config Mode
1
1 Leave Config Mode
2
2 Session Timeout
10
1 DHCP Client State
11
4 Set IP Address
15
4 Set Subnet Mask
19
4 Set Gateway Address
27
1 Store Eth Parameters
32
1 OPC UA State
50
1 Time Sync Mode
51
4 NTP Server 1
55
4 NTP Server 2
100
1 Exposure Time
101
1 Precision
200
8 Field of View
220
1 Set Field of View to MAX
250
1 Reset Flex Mount
251
4 Flex Mount
255
2 Teach Flex Mount
300
11 Switching Output Configuration
400
8 Trigger Mode
410
1 Laser On/Off
500
1 Store Setting
501
1 Load Setting
502
1 Reset Setting
503
1 Sensor Reset
Address 0 – Enter Config Mode
Writing any value to this register sets the sensor to Configuration mode. The write command fails if the sensor
has already been set to Configuration mode via another interface.
Function
Holding register (FUNCTION 03/06/16)
Address
0
Length
1
Access
Write Only
Address
Parameter description
Data type
0
Enter Config Mode:
uint16_t
4.2.3.1
4.2.3.1