en_BA_OXH7_PosCon_TCP_IP.docx
56/98
Baumer Electric AG
Friday, June 15, 2018 12:44:11 PM/tof V1.0 ANW_81184815
Frauenfeld, Switzerland
Address 11 – Set IP Address
Shadow register for setting the sensor's IP address. Once this entry has been written, the subnet mask and
the standard gateway address can still be set. The changes are only activated once the "Store Ethernet
Parameter" command has been executed.
Function
Holding register (FUNCTION 03/06/16)
Address
11
Length
4
Access
Write Only
Address
Parameter description
Data type
11
IP Address Byte 0
uint16_t
12
IP Address Byte 1
uint16_t
13
IP Address Byte 2
uint16_t
14
IP Address Byte 3
uint16_t
Address 15 – Set Subnet Mask
Shadow register for setting the sensor's subnet mask. Once this entry has been written, the IP address and
the standard gateway address can still be set. The changes are only activated once the "Store Ethernet
Parameter" command has been executed.
Function
Holding register (FUNCTION 03/06/16)
Address
15
Length
4
Access
Write Only
Address
Parameter description
Data type
15
Subnet Mask Byte 0
uint16_t
16
Subnet Mask Byte 1
uint16_t
17
Subnet Mask Byte 2
uint16_t
18
Subnet Mask Byte 3
uint16_t
Address 19 – Set Gateway Address
Shadow register for setting the sensor's standard gateway address. Once this entry has been written, the IP
address and the subnet mask can still be set. The changes are only activated once the "Store Ethernet
Parameter" command has been executed.
Function
Holding register (FUNCTION 03/06/16)
Address
19
4.2.3.1
4.2.3.1
4.2.3.1