Commissioning
|
7
V2 | OM20/OM30 IO-Link
Operating Manual
23
7
Commissioning
7.1
Factory settings
Adjustable parameters
Factory setting of the sensor
Operation Mode
Precision Filter
Highest
Sampling Mode
Free Running
Measurement Range
Zero Position
0 mm
Distance Near
Sdc
Distance Far
Sde
Invalid Value Handling
Value after Dropout
Near
Hold Time
0 ms
SSC1 Configuration
SP 1
Sde -10 mm
I
SP 2
Sdc +10 mm
II
Polarity
Active High
Mode
Window
Hysteresis
depending on MR
Input/Output Settings
OUT1 Mode
(Output & LED function)
SSC1 - Alarm
Analog Output
Output Type
4 ... 20 mA /
0 ... 10 VDC
Output Characteristic
Not inverted
Distance @AnalogMin
Sdc
Distance @AnalogMax
Sde
Local User Interface
Local Teach Mode
XPert
Button Time Out
5 min
Device Access Locks
Data Storage Lock
False
I
Type OM20-P0026.xx.xxx: SSC1 Param.SP 1 =
-2 mm
II
Type OM20-P0026.xx.xxx: SSC1 Param.SP 2 =
+2 mm
7.2
Setting up IO-Link
Instruction:
w
Download the IODD file for the sensor from one of the following two websites (the IODD file
can be found via the item number of the sensor):
or