Baumer
Description
|
3
V2 | OM20/OM30 IO-Link
Operating Manual
15
IO-Link process data: Output
Sub-
Index
Bit-
Offset
Denotation
Data type
Description
1
1
Find me
Boolean
n
Switch the laser on/off.
2
0
Laser ON/ OFF
Boolean
n
Localize the sensor by activating the
LEDs.
IO-Link process data: input
Sub-
Index
Bit-
Offset
Denotation
Data type
Description
1
16
Distance (MDC)
32 Bit Integer
n
Measured value
2
8
Scale
8 Bit Integer
n
Scale of the measured value
n
The transmitted scale value corre-
sponds to exponents of 10
(i.e.: 10
Scale
).
n
Formula for calculating the measure-
ment value:
▪ Measurement value (MDC
I
) × 10
Scale
× Unit
n
Example:
▪ Measurement value (MDC):
1000
▪ Scale:
-6
▪ Unit:
m
▪ Therefore:
1000
×
10
-6
×
m
=
1000
µm
7
3
Output
Boolean
n
Status of the alarm output
▪ Bit 3 = 0: Alarm is inactive. Sensor is
functioning as required.
▪ Bit 3 = 1: Alarm is active. The sen-
sor must be checked. No measured
value can be recorded.
8
2
Quality Bit
Boolean
n
Status of the signal quality.
▪ Bit 2 = 0: Signal quality is sufficient
for a valid measurement.
▪ Bit 2 = 1: Signal quality is insuffi-
cient. The sensor must be checked
(e.g. for soiling).
10
0
SSC1
(Switching Signal
Channel 1)
Boolean
n
Status of the switching output.
▪ Bit 0 = 0: Switching output is inac-
tive.
▪ Bit 0 = 1: Switching output is active.
I
MDC = Measurement Data Channel