Baumer_GIM700DR_CANopen_EN_V1.00_MNL.docx
www.baumer.com
27.04.21
31/32
5.1.3
2-dimensional sensor / vertical installation / plumb angle ±90° (2D-VP)
Install sensor in vertical position with horizontal Z-axis and Y-axis (see illustration).
Sensor measures rotation around Z-axis and Y-axis with measuring range ±90°.
Sensor outputs / slope values increase during clockwise rotation.
Sensor outputs are zero / 0°, when Z-axis and Y-axis have horizontal alignment (factory default set-
tings).
Zero degree positions may be configured by Slope long preset value objects (6012h, 6112h) and
Slope lateral preset value objects (6022h, 6122h).
Z-axis angle = 0°
Y-axis angle = 0°
Z-axis angle = +30°
Y-axis angle = 0°
Z-axis angle = +45°
Y-axis angle = 0°
Z-axis angle = 0°
Y-axis angle = 0°
Z-axis angle = 0°
Y-axis angle = -30°
Z-axis angle = 0°
Y-axis angle = -45°
Z
+
Y
+