Baumer_GIM700DR_CANopen_EN_V1.00_MNL.docx
www.baumer.com
27.04.21
19/32
Object
Sub-index
Name
Format
Access
Default
Save
04h
Restore default manufacturer
parameters
U32
rw
For device profile specific parameters (CiA DS-
410) marked with Save yes
1014h Emergency COB-ID
U32
rw
80h + Node-ID
yes
1016h Consumer heartbeat time
yes
00h Highest sub-index supported
U8
ro
1h
01h Consumer heartbeat time
U32
rw
0h
yes
1017h Producer heartbeat time
U16
rw
0h
yes
1018h Identity object
00h Highest sub-index supported
U8
ro
4h
01h Vendor-ID
U32
ro
ECh
02h Product code
U32
ro
1D: 60h
2D: 61h
03h Revision number
U32
ro
04040001h or higher
yes
04h Serial number
U32
ro
Factory-defined
yes
1800h TX PDO1 communication
Transmit PDO1 communication parameters
00h Highest sub-index supported
U8
ro
5h
01h COB-ID
U32
rw
$40000180h
yes
02h PDO transmission type
U8
rw
FFh
yes
05h Event time
U16
rw
C8h
yes
1801h TX PDO2 communication
Transmit PDO2 communication parameters
00h Highest sub-index supported
U8
ro
5h
01h COB-ID
U32
rw
$40000280h
yes
02h PDO transmission type
U8
rw
FFh
yes
05h EventTimer
U16
rw
0h
yes
1802h TX PDO3 communication
Transmit PDO3 communication parameters
00h Highest sub-index supported
U8
ro
5h
01h COB-ID
U32
rw
$40000380h
yes
02h PDO transmission type
U8
rw
FFh
yes
05h Event time
U16
rw
0h
yes
1803h TX PDO4 communication
Transmit PDO4 communication parameters
00h Highest sub-index supported
U8
ro
5h
01h COB-ID
U32
rw
$40000480h
yes
02h PDO transmission type
U8
rw
FFh
yes
05h Event time
U16
rw
0h
yes
1A00h TX PDO1 mapping
Transmit PDO1 mapping parameters
00h Highest sub-index supported
U8
rw
1D: 2h (1-dim slope sensor)
2D: 3h (2-dim slope sensor, horizontal & vertical
installation)
yes
01h Mapping entry 1
U32
rw
1D: 65110010h (device temperature)
2D: 65110010h (device temperature)
yes
02h Mapping entry 2
U32
rw
1D-VP: 60100010h (Slope long 16-bit, Z-axis,
plumb angle,
0…360°)
2D-HP: 60100010h (Slope long 16-bit, X-axis,
horizontal installation, plumb angle, ±90°)
2D-VP: 60100010h (Slope long 16-bit, Z-axis,
vertical installation, plumb angle, ±90°)
yes