Baumer_GIM700DR_CANopen_EN_V1.00_MNL.docx
www.baumer.com
27.04.21
15/32
COB-ID cs
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Switch state global
7E5h
04h
State
reserved
State : 0
Operation
al state
: 1
Configuration
state
Switch state selective
The following procedure can be used to address a certain sensor in the bus system.
7E5h
40h
Vendor ID
reserved
7E5h
41h
Product code
reserved
7E5h
42h
Revision number
reserved
7E5h
43h
Serial number
reserved
7E4h
44h
State
reserved
Vendor ID
: ECh
Product code
: Internal product code for the respective sensor
Revision number : Current revision number of the sensor
Serial number
: Unique, consecutive serial number
State
: The sensor's response is the new state (0=operating state; 1=configuration state)
Setting node-ID
7E5h
11h
Node-ID reserved
7E4h
11h
ErrCode Spec error
reserved
Node-ID
: The sensor's new Node-ID
Error code
: 0=OK; 1=Node-ID outside range; 2...254=reserved; 255
Specific error
Specific error
: If Error code=255
application-specific error code.
Setting bit timing
7E5h
13h
Ta-
bleSel
TableInd reserved
7E4h
13h
ErrCode SpecError reserved
TableSel
: Selects the bit timing table
0
: Standard CiA bit timing table
TableInd
: Bit timing entry in selected table (see table below).
Error code
: 0=OK; 1=Bit timing outside range; 2...254=reserved; 255
Specific error
Specific error
: If Error code=255
Application-specific error code.