Baumer_GIM700DR_CANopen_EN_V1.00_MNL.docx
www.baumer.com
27.04.21
24/32
Gyroscope sensor: Filter order (2108h-2)
Value
Description
1
…8
Order of the filter.
Only effective, if 2108h-1h = 1 (low-pass filter) or 2 (band-pass filter).
In case of 2108h-1h = 2 (band-pass filter) only even numbers are valid.
Gyroscope sensor: Filter cut-off frequency 1 (2108h-3)
Value
Description
100
…3000
Cut-off frequency 1 (upper cut-off) with resolution 0.01 Hz (30 Hz
BB8h).
If 2108h-1h = 0
no effect.
If 2108h-1h = 1 (low-pass filter)
low-pass cut-off.
If 2108h-1h = 2 (band-pass filter)
low-pass cut-off.
Gyroscope Sensor: Filer cut-off frequency 2 (2108h-4)
Value
Description
100
…3000
Cut-off frequency 2 (lower cut-off) with resolution 0.01 Hz (1 Hz
64h).
If 2108h-1h = 0
no effect.
If 2108h-1h = 1
no effect.
If 2108h-1h = 2 (band-pass filter)
high-pass cut-off.
Note: For correct band-pass filter operation, cut-off frequency 1 must be set higher than cut-off frequency 2. A
plausibility check is not implemented.
4.2.3.3
Filter settings: Process data (2109h)
This filter affects the following process data (sensor fusion data): Slope longitudinal / lateral, Euler angles,
Quaternion.
Process data: Filter type (2109h-1h)
Value
Description
0
No filter
1
Low-pass filter (Butterworth type)
Process data: Filter order (2109h-2h)
Value
Description
1
…8
Order of the filter
Only effective, if 2109h-1h = 1 (low-pass filter)
Process data: Cut-off frequency (2109h-3h)
Value
Description
100...3000
Cut-off frequency with resolution 0.01 Hz (30 Hz
BB8h)
Only effective, if 2109h-1h = 1 (low-pass filter)