background image

BatteryMINDer

®    

Model 483CEC1

Rev. A-051216 

Page 13 

P/N 483CEC1-MNL

battery set to maintain a constant voltage.  As the battery set nears a full 

charge, the current needed to maintain this voltage decreases.  Once the 

current falls below a 0.10A change per hour, the stage is complete.  It will 

be in this stage for a minimum of one hour.

•  Battery Test

 is administered by reading your battery set's voltage while 

resting the battery set for 10 minutes.  A voltage of under 50.0V indicates 

a weak battery set, under 46.0V indicates a shorted cell.  The battery 

set is tested at completion of the Constant Voltage stage, and every 12 

hours while in 

Float.

•  Float

 (sometimes called Maintenance) is the maintenance-charger’s 

long term stage.  The maintenance-charger can and should be left 

connected indefinitely.  This will keep the battery set fully charged 

ensuring no sulfate can form.  The maintenance-charger maintains float 

voltage using very little power as it actively monitors the battery set and 

adjusts its output several times a second.  

Indicator Light Details

•  Power

 light is 

GREEN

 anytime the maintenance-charger is plugged into 

AC Power.

•  Battery Connection

 light is 

GREEN

 when the unit it is correctly 

connected to a battery set.  If the 

Battery Connection

 light is 

RED

 the 

polarity is reversed.  The positive and negative terminals need to be 

switched or there is a short circuit.

•  Battery Weak

 light is 

AMBER

 if the 

Soft-Start

 mode is used or the 

battery set fails a Battery Test.  The indicator will stay on until the battery 

set passes a Battery Test.

A neglected battery set can take over 2 weeks of desulfation to correct.  

If after 2 weeks it still reads as a Weak Battery, there is likely internal 

physical damage.

•  Bad Cell

 if the battery set is under 46.0V after a 

Battery Test

.  

The maintenance-charger shuts off output to avoid any damage to your 

battery set.  Loads or banks of batteries may trigger this mode if they are 

too large for this maintenance-charger.  

•  Testing

 light is 

BLUE

 when the unit is performing a 

Battery Test 

(see 

Charging Stages

).

•  Desulfation

 light flashes 

BLUE

 any time the unit is desulfating.  The 

Содержание 483CEC1

Страница 1: ...43 www BatteryMINDers com techsupport vdcelectronics com BatteryMINDer COMMERCIAL 48 Volt Model 483CEC1 Battery Maintainer Charger Desulfator INSTRUCTION MANUAL Includes ATS Temperature Sensor install...

Страница 2: ...ate crystals build up in the plates The large sulfate crystals increase the resistance of the plates and makes the battery harder to recharge and reduces the amount of power that can be drawn from the...

Страница 3: ...pull by plug rather than cord when disconnecting maintenance charger Make sure cord is located so that it will not be stepped on tripped over or otherwise subjected to damage or stress 6 An extension...

Страница 4: ...unning cold water for at least 10 minutes and get medical attention immediately 5 NEVER smoke or allow a spark or flame in vicinity of battery 6 Be extra cautious to reduce risk of dropping a metal to...

Страница 5: ...attery will corrode and damage maintenance charger 3 Never allow battery acid to drip on maintenance charger when reading electrolyte specific gravity or filling battery 4 Do not operate maintenance c...

Страница 6: ...s that could have caused sulfation such as high temperature storage 80 F and or allowed to self discharge to 2 06 Volts cell 49 4V battery set even before you purchased it then you can disregard our r...

Страница 7: ...batteries have no filler caps or manifold type covers Because you cannot gain access to the interior of your battery you cannot test it with a hydrometer USE A DIGITAL VOLTMETER ONLY 1 Recharge the ba...

Страница 8: ...Connection Precautions Unit Location and Qualifying Your Battery Set BEFORE proceeding further 1 Install Ring Terminal Assembly RTA 2415 to the first and last battery in the series connected 48 V gro...

Страница 9: ...Temperature Sensor input connector with ATS 1 Ambient Temperature Sensor installed included 5 Output cord with quick connect plug 6 Ring Terminal cordset with quick connect plug included 7 Mounting t...

Страница 10: ...ING ECO mode no battery set connected very low standby power mode None required 3B BATTERY WEAK Battery set s voltage is low at start of charge OR voltage is low after testing stage Allow BatteryMINDe...

Страница 11: ...BatteryMINDer Model 483CEC1 Rev A 051216 Page 11 P N 483CEC1 MNL BatteryMINDer 483CEC1 Unit Label close up VDC 483CEC1 LABEL P N 701 100476 01 R 2 1 3 A A D C B D C B E G F...

Страница 12: ...mperature 27 C 80 F Blue Steady Ambient temperature 21 C 70 F VOLTAGE LOW AMBER REJECTED RED Initial qualification of the battery set s condition at the beginning of Soft Start stage Amber Steady Volt...

Страница 13: ...monitors the battery set and adjusts its output several times a second Indicator Light Details Power light is GREEN anytime the maintenance charger is plugged into AC Power Battery Connection light i...

Страница 14: ...er and three times the life of conventional batteries The Wet cell comes in two styles Serviceable and Maintenance free Both are filled with electrolyte and are basically the same AGM absorbed glass m...

Страница 15: ...lk LED Indicator will light GREEN The maintenance charger will now begin charging by first checking the battery set to determine its voltage and ability to accept a charge Should the battery set not h...

Страница 16: ...rcentage 48V 51 6 52 4 100 50 4 51 6 75 49 6 50 4 50 48 8 49 6 25 48 0 48 8 0 44 shorted EZC 01 Installation The EZC 01 Connector is universal flush mountable for use on any BatteryMINDer Charger Main...

Страница 17: ...safely discarded recycled Battery Set Weak Indicator lights RED blinking Battery set may be weak heavily sulfated or too large to fully charge before unit times out Battery set may be so large it may...

Страница 18: ...___________________________________________________ _______________________________________________________ _______________________________________________________ ____________________________________...

Страница 19: ..._________________________ RMA ___________________________ Please register your unit on line within 10 days of purchase Due to the ever changing technology associated with this BatteryMINDer unit we ma...

Страница 20: ...our BatteryMINDer product is warrantied for FIVE years from date of purchase at retail against defective material or workmanship We make no warranty other than this limited warranty and expressly excl...

Отзывы: